date 04/18/2017 │ page 3 of 7CUI Inc │ SERIES: PQME3-M │ DESCRIPTION: DC-DC CONVERTER
SAFETY AND COMPLIANCE
(
CONTINUED
)
parameter conditions/description min typ max units
radiated emissions CISPR22/EN55022, class B (external circuit required, see Figure 2-b)
ESD IEC/EN61000-4-2, contact ± 4kV, class B
radiated immunity IEC/EN61000-4-3, 10V/m, class A
EFT/burst IEC/EN61000-4-4, ± 2kV, class B (external circuit required, see Figure 2-a)
surge IEC/EN61000-4-5, line-line ± 2kV, class B (external circuit required, see Figure 2-a)
conducted immunity IEC/EN61000-4-6, 3 Vr.m.s, class A
voltagedips&interruptions IEC/EN61000-4-29, 0%-70%, class B
MTBF as per MIL-HDBK-217F, 25°C 1,000,000 hours
RoHS 2011/65/EU
ENVIRONMENTAL
parameter conditions/description min typ max units
operating temperature see derating curve -40 85 °C
storage temperature -55 125 °C
storage humidity non-condensing 5 95 %
case temperature rise Ta=25°C,atnominalinputvoltage,fullload 40 °C
vibration 10~55 Hz for 30 minutes on each axis 10 G
SOLDERABILITY
parameter conditions/description min typ max units
reowsoldering
Maximum duration >217°C is 60 seconds.
For actual application, refer to IPC/JEDEC J-STD-020D.1
245 °C
MECHANICAL
parameter conditions/description min typ max units
dimensions 19.20 x 18.10 x 10.16 [0.756 x 0.713 x 0.400 inch] mm
case material blackame-retardantheat-proofplastic
weight 3.5 g