BK/GLQ-1-1/2

Catalog Symbol: GLQ (Fuse) HLQ (Fuseholder)
Fast-Acting Rejection Style
Ampere Rating: 1-10 Amperes
Voltage Rating: 300 Volts AC or less
Interrupting Rating: 10,000 Amperes
Agency Information:
Fuse:
UL Listed, Std. 248-14, Guide JDYX, File E19180
CSA Certified, C22.2 No. 248.14, Class 1422-01, File 53787
Fuseholder:
UL Recognized, Guide IZLT2, File E14853
CSA Certified, Class 6225-01, File 47235
Specialty Fuse GLQ
Fast-Acting, Size Rejecting
& HLQ
Form No. GLQ & HLQ
Page 1 of 1
Data Sheet: 2033
Bussmann
®
5-22-02
SB02233
0.63"
(15.9mm)
FUSE
The only controlled copy of this Data Sheet is the electronic read-only version located on the Bussmann Network Drive. All other copies of this document are by definition uncontrolled. This bulletin is
intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Bussmann reserves the right, without notice, to change
design or construction of any products and to discontinue or limit distribution of any products. Bussmann also reserves the right to change or update, without notice, any technical information con-
tained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications.
Dimensional Data
.1
1
10
100
200
CURRENT IN AMPERES
AMPERE
RATING
5
1.5
100
10
1
.1
.01
TIME IN SECONDS
15
1
2
10
Electrical Ratings for Type GLQ Fuses and Rejection
Style Carriers
Fuse Carrier Fuse Carrier
GLQ-1 HLQ-1flΩ¡º GLQ-3 HLQ-3¤Ω¡º
GLQ-1⁄Ω™ HLQ-1flΩ¡º GLQ-4 HLQ-5
GLQ-1flꭧ HLQ-1flꭧ GLQ-5 HLQ-5
GLQ-2 HLQ-3¤Ω¡º GLQ-9 HLQ-10
GLQ-2⁄Ω™ HLQ-3¤Ω¡º GLQ-10 HLQ-10
Time-Current Characteristic Curves–Average Melt
General Information:
• Size of GLQ fuse varies with ampere rating.
• GLQ fuses mount in HLQ size rejecting carriers (prevents
overfusing).
• Fuse and knob are an integral one-piece unit. There are no
replacement knobs (caps).
• HLQ carrier comes with
6∑ of #18 red insulated solid copper
wire attached to the line side.
• Customer inserts a #18 insulated solid copper wire into load
side receptacle.
• Units can be panel mounted with a separate steel clip. For
the knockout hole (see above), choose #BK/A-104. For the
keyhole punch type hole, choose #6374 for panels .043” to
.062” thick, or #4909 for panels .030” to .042” thick.
• Do not put tension on line (rear) terminal of fuse-holder.
CE logo denotes compliance with European Union Low Voltage Directive
(50-1000 Vac, 75-1500 Vdc). Refer to Data Sheet: 8002 or contact
Bussmann Application Engineering at 636-527-1270 for more information.
.720''
C
L
.850''
.850''
2.250''
.740''
.870''
.635''
.255''
.410''
Keyhole PunchKnockout Hole
Load Lead
Line Lead
18.29mm
21.59mm
21.59mm
57.15mm
22.10mm
18.80mm
6.48mm
16.13mm
10.41mm
FUSE AND CARRIER
MOUNTING HOLE

BK/GLQ-1-1/2

Mfr. #:
Manufacturer:
Description:
Specialty Fuses SMALL DIMENSION FUSE
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment: