5 06/16
Please read Cautions and warnings and
Important notes at the end of this document.
Technical data and measuring conditions
Rated voltage V
R
42 V AC (50/60 Hz) / 80 V DC
Test voltage V
test
250 V DC, 2 s (line/line)
Rated temperature T
R
+85 °C / +110 °C
Rated current I
R
Referred to 50 Hz and rated temperature
Rated inductance L
R
Measured with Agilent 4284A at 100 kHz, 0.1 mA, +20 °C
Inductance is specified per winding.
Inductance tolerance –30/+50% at +20 °C
Inductance decrease'L/L
0
Common mode < 10% at DC magnetic bias with I
R
, +20 °C
Stray inductance L
stray,typ
Measured with Agilent 4284A at 100 kHz, 5 mA, +20 °C,
typical values
DC resistance R
max
Measured at +20 °C, specified per winding
Solderability (lead-free) Dip and look method Sn95.5Ag3.8Cu0.7: +(245 r5) °C, (3 r0.3) s
Wetting of soldering area t90%
(based on IEC 60068-2-58)
Resistance to soldering heat +260 °C, 40 s as referenced in JEDEC J-STD 020D
Climatic category 55/125/56 (B82789*N)
55/150/56 (B82789*H)
(to IEC 60068-1)
Storage conditions Mounted: –55 °C … +125 °C (B82789C0/S0*N)
–55 °C … +150 °C (B82789C0/S0*H)
Packaged: –25 °C … +40 °C, d75% RH
Weight Approx. 0.16 g
B82789C0/S0Data and signal line chokes
SIMDAD 1812, common-mode chokes