TEN 6-4810WIN

http://www.tracopower.com Page 1 of 3
DC/DC Converters
TEN 6WIN Series, 6 Watt
UL 60950-1
C B
Scheme
IEC 60950-1
Order code Input voltage Output voltage Output current Efficiency typ.
1‘500 VDC isolation 3‘000 VDC isolation
range max.
TEN 6-2410WIN TEN 6-2410WIN-HI
3.3 VDC 1200 mA 77 %
TEN 6-2411WIN TEN 6-2411WIN-HI
5 VDC 1200 mA 80 %
TEN 6-2412WIN TEN 6-2412WIN-HI
12 VDC 500 mA 84 %
TEN 6-2413WIN TEN 6-2413WIN-HI 9 – 36 VDC
15 VDC 400 mA 84 %
TEN 6-2415WIN TEN 6-2415WIN-HI
(24 VDC nominal)
24 VDC 250 mA 84 %
TEN 6-2421WIN TEN 6-2421WIN-HI
±5 VDC ±500 mA 80 %
TEN 6-2422WIN TEN 6-2422WIN-HI
±12 VDC ±250 mA 84 %
TEN 6-2423WIN TEN 6-2423WIN-HI
±15 VDC ±200 mA 84 %
TEN 6-4810WIN TEN 6-4810WIN-HI
3.3 VDC 1200 mA 77 %
TEN 6-4811WIN TEN 6-4811WIN-HI
5 VDC 1200 mA 80 %
TEN 6-4812WIN TEN 6-4812WIN-HI
12 VDC 500 mA 84 %
TEN 6-4813WIN TEN 6-4813WIN-HI 18 – 75 VDC
15 VDC 400 mA 84 %
TEN 6-4815WIN TEN 6-4815WIN-HI
(48 VDC nominal)
24 VDC 250 mA 84 %
TEN 6-4821WIN TEN 6-4821WIN-HI
± 5 VDC ±500 mA 80 %
TEN 6-4822WIN TEN 6-4822WIN-HI
±12 VDC ±250 mA 84 %
TEN 6-4823WIN TEN 6-4823WIN-HI
±15 VDC ±200 mA 84 %
Models
Features
Wide 4:1 input voltage range
High efficiency
Operating temperature range
40°C to +85°C
No minimum load required
Models with 1500 VDC and 3’000 VDC
I/O isolation (functional insulation)
Input filter meets EN 55022, class A
Overload protection
DIP-24 plastic package
Industry standard pinout
3-year product warranty
The TEN-6WIN series is designed for an optimized cost/performance ratio of
DC/DC converters with output power of 6 Watt.
General features like no minimum load requirement, overload protection, internal
filter for EN55022 class A and high efficiency make these converters easy to design
in. With the popular DIP-24 standard package they are also a drop in replacement
for many cost critical applications.
http://www.tracopower.com Page 2 of 3
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
DC/DC Converters
TEN 6WIN Series 6 Watt
Input Specifications
Input current at no load 24 Vin models: 20 mA typ.
48 Vin models: 10 mA typ.
Input current at full load 24 Vin, 3.3VDC models: 215 mA typ.
24 Vin other models: 300 mA typ.
48 Vin, 3.3VDC models: 110 mA typ.
48 Vin other models: 150 mA typ.
Recommended input fuse (slow blow) 24 Vin models: 1500 mA
48 Vin models: 800 mA
Start-up voltage / under voltage shut down 24 Vin models: 9 VDC / 8.5 VDC (or lower)
48 Vin models: 18 VDC / 16 VDC (or lower)
Surge voltage (1 sec. max.) 24 Vin models: 50 V max.
48 Vin models: 100 V max.
Conducted noise EN 55022 class A
Output Specifications
Voltage set accuracy ±2 %
Regulation – Input variation Vin min. to Vin max. 0.5 % max.
– Load variation 0 – 100 % single output models: 1.2 % max.
dual output models balanced load: 1.2 % max.
dual output models 50%/100% unbalanced load: 3.0 % max.
Minimum load not required
Temperature coefficient ±0.02 %/K
Ripple and noise (20 MHz Bandwidth) 80 mVp-p max.
Dynamic load response (change from 75 % to 100 % load) ±3 % peak variation typ.
300 μS response time typ.
Current limitation 150 % of Iout max. typ., constant power
Short circuit protection continuous, automatic recovery
Capacitive load 3.3 & 5.0 VDC models: 470 μF max.
12 & 15 VDC models: 100 μF max.
24 VDC models: 47 μF max.
dual output models: 100 μF max. (each output)
General Specifications
Temperature ranges – Operating –40°C to +85°C
– Case temperature +100°C max.
– Storage –50°C to +125°C
Derating 3.3 & 5.0 VDC models: 2.5 %/K above +60°C
other models: 3.3 %/K above +70°C
Humidity (non condensing) 95 % rel H max.
Reliability, calculated MTBF (MIL-HDBK-217F, at +25°C, ground benign) >800‘000 h
Isolation voltage (input/output, 60 sec., functional insulation) standard models: 1500 VDC
models with suffix -H: 3‘000 VDC
Isolation capacitance (input/output, 100 KHz, 1 V) 1000 pF typ.
Isolation resistance (input/output, 500 VDC) >1‘000 M Ohm
Switching frequency 330 kHz typ.
Page 3 of 3
Specifications can be changed without notice! Make sure you are using the latest documentation, downloadable at www.tracopower.com
www.tracopower.com
DC/DC Converters
TEN 6WIN Series 6 Watt
Outline Dimensions
Pin Single Dual
2
–Vin (GND) –Vin (GND)
3
–Vin (GND) –Vin (GND)
9
No pin Common
11
No function –Vout
14
+Vout +Vout
16
–Vout Common
22
+Vin (Vcc) +Vin (Vcc)
23
+Vin (Vcc) +Vin (Vcc)
Pin-Out
Rev. July 11. 2018
General Specifications
Safety approvals – CSA certificate of compliance CAN/CSA-C22.2 No 60950-1-07, Am 1:2011
ANSI/UL Std No 60950-1, 2nd Ed, AM 1:2011
– CB test certificate IEC 60950-1:2005 2nd Ed, Am 1:2009
EN 60950-1:2006, +A11:2009, +A1:2010,
+ A12 :2011
certification documents www.tracopower.com/overview/ten6win
Environmental compliance – Reach www.tracopower.com/info/reach-declaration.pdf
– RoHS RoHS directive 2011/65/EU
Physical Specifications
Casing material non conductive plastic (UL 94V-0-rated)
Potting material epoxy (XM-2109 & XY-2110, UL 94V-0-rated)
Weight 13.0 g (0.46 oz)
Soldering temperature (1.5mm from case for 10 sec.) max. 260°C
911
2223
23
16 14
Bottom view
15.24
2.54
20.3
(0.10)
(0.60)
(0.80)
10.2
(0.40)4.1
(0.16)
2.54 15.24 5.08
4.5
31.8
(0.10)
(0.60)
(0.20)
(0.18)
(1.25)
Dimensions in [mm], () = Inch
Pin diameter ø 0.5 ±0.05 (0.02 ±0.002)
Tolerances ±0.25 (±0.01)
Pin pich tolerances ±0.13 (±0.0005)
Supporting documents: www.tracopower.com/overview/ten6win

TEN 6-4810WIN

Mfr. #:
Manufacturer:
TRACO Power
Description:
Isolated DC/DC Converters
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union