DMC16230NY-LY-AVE (DQ) No.99-0206 OPTREX CORPORATION Page 10/16
OPTREX
5.Test
No change on display and in operation under the following test condition.
No. Parameter Conditions Notes
1 High Temperature Operating 50
℃±
2
, 96hrs (operation state)
2 Low Temperature Operating 0
℃±
2
, 96hrs (operation state) 3
3 High Temperature Storage 70
℃±
2
, 96hrs 4
4 Low Temperature Storage -20
℃±
2
, 96hrs 3, 4
5 Damp Proof Test 40
℃±
2
, 90
95%RH, 96hrs 3, 4
6 Vibration Test Total fixed amplitude : 1.5mm 5
Vibration Frequency : 10
55Hz
One cycle 60 seconds to 3 directions of X, Y, Z for
each 15 minutes
7 Shock Test To be measured after dropping from 60cm high on
the concrete surface in packing state.
Note 1 : Unless otherwise specified, tests will be conducted under the following condition.
Temperature : 20
±
5
Humidity : 65
±
5%
Note 2 : Unless otherwise specified, tests will be not conducted under functioning state.
Note 3 : No dew condensation to be observed.
Note 4 : The function test shall be conducted after 4 hours storage at the normal temperature and humidity
after removed from the test chamber.
Note 5 : Vibration test will be conducted to the product itself without putting it in a container.
E
A
G
D
C
F
60cm
Concrete Surface
Dropping method corner dropping
E,F,G face : once
B,C,D edge : once
A corner : once
Face dropping
Edge dropping
B
DMC16230NY-LY-AVE (DQ) No.99-0206 OPTREX CORPORATION Page 11/16
OPTREX
6.Appearance Standards
6.1.Inspection conditions
The LCD shall be inspected under 40W white fluorescent light.
The distance between the eyes and the sample shall be more than 30cm.
All directions for inspecting the sample should be within 45
against perpendicular line.
6.2.Definition of applicable Zones
A Zone : Active display area
B Zone : Area from outside of "A Zone" to validity viewing area
C Zone : Rest parts
A Zone + B Zone = Validity viewing area
A Zone
B Zone
C Zone
Bezel Flame
45
DMC16230NY-LY-AVE (DQ) No.99-0206 OPTREX CORPORATION Page 12/16
OPTREX
6.3.Standards
No. Parameter Criteria
1 Black and (1) Round Shape
White Spots, Zone Acceptable Number
Foreign Substances Dimension (mm) A B C
D
0.1 * * *
0.1
D
0.2 5 5 *
0.2
D
0.3 0 1 *
0.3
D 0 0 *
D = ( Long + Short ) / 2 * : Disregard
(2) Line Shape
Zone Acceptable Number
X(mm) Y(mm) A B C
0.02
W * * *
2.0
L 0.03
W 3 3 *
1.0
L 0.04
W 1 2 *
1.0
L 0.05
W 0 2 *
0.05
W In the same way (1)
X : Length Y : Width * : Disregard
Total defects shall not exceed 5.
2 Air Bubbles
(between glass Zone Acceptable Number
& polarizer) Dimension (mm) A B C
D
0.15 * * *
0.15
D
0.3 2 3 *
0.3
D
0.5 1 2 *
0.5
D
1.0 0 1 *
* : Disregard
Total defects shall not exceed 3.

DMC-16230NY-LY-AVE

Mfr. #:
Manufacturer:
Kyocera Display
Description:
LCD Character Display Modules & Accessories Yellow Transmissive Yellow LED Backlight
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet