TC74HC4051,4052,4053AP/AF/AFT
2016-10-18
Absolute Maximum Ratings (Note 1)
Characteristics Symbol Rating Unit
Supply voltage range V
CC
-0.5 to 7 V
Supply voltage range V
CC
-V
EE
-0.5 to 13 V
Control input voltage V
IN
-0.5 to V
CC
+ 0.5 V
Switch I/O voltage V
I/O
V
EE
- 0.5 to V
CC
+ 0.5 V
Control input diode current I
CK
±20 mA
I/O diode current I
IOK
±20 mA
Switch through current I
T
±25 mA
DC V
CC
or ground current I
CC
±50 mA
Power dissipation P
D
500 (DIP) (Note 2)/180 (SOP/TSSOP) mW
Storage temperature T
stg
-65 to 150 °C
Note 1: Exceeding any of the absolute maximum ratings, even briefly, lead to deterioration in IC performance or
even destruction.
Using continuously under heavy loads (e.g. the application of high temperature/current/voltage and the
significant change in temperature, etc.) may cause this product to decrease in the reliability significantly
even if the operating conditions (i.e. operating temperature/current/voltage, etc.) are within the absolute
maximum ratings and the operating ranges.
Please design the appropriate reliability upon reviewing the Toshiba Semiconductor Reliability Handbook
(“Handling Precautions”/“Derating Concept and Methods”) and individual reliability data (i.e. reliability test
report and estimated failure rate, etc).
Note 2: 500 mW in the range of Ta = -40 to 65°C. From Ta = 65 to 85°C a derating factor of -10 mW/°C should be
applied up to 300 mW.
Operating Ranges (Note)
Characteristics Symbol Rating Unit
Supply voltage range V
CC
2 to 6 V
Supply voltage range V
EE
-6 to 0 V
Supply voltage range V
CC
-V
EE
2 to 12 V
Control input voltage V
IN
0 to V
CC
V
Switch I/O voltage V
I/O
V
EE
to V
CC
V
Operating temperature T
opr
-40 to 85 °C
Control input rise and fall time t
r
, t
f
0 to 1000 (V
CC
= 2.0 V)
0 to 500 (V
CC
= 4.5 V)
0 to 400 (V
CC
= 6.0 V)
ns
Note: The operating ranges must be maintained to ensure the normal operation of the device.
Unused control inputs must be tied to either V
CC