2
Plastic Optical Fiber Specications: AFBR-HUXYYYZ
Absolute Maximum Ratings
Parameter Symbol Min. Max. Unit Note
Recommended Storage Temperature T
S
-55 +85 °C
Recommended Operating Temperature T
O
-40 +85 °C
Recommended Installation Temperature T
i
-20 +70 °C 1
Short Term Tensile Force (simplex) F
T
50 N 2, 3
Short Term Bend Radius r 20 mm 2, 4, 5
Long Term Bend Radius r 35 mm 6, 4, 5
Long Term Tensile Load (simplex) F
T
1 N 6, 3
Flexing (r=20mm) 1000 Cycles 7, 8
UL VW-1 Flame Retardant
Mechanical Characteristics, T
A
= -40°C to +85°C unless otherwise specied
Parameter Symbol Min. Typ.
[12]
Max. Unit Note
Numerical Aperture NA 0.48 9
Diameter Core and Cladding DC 0.94 1.00 1.06 mm
Diameter Jacket DJ 2.13 2.20 2.27 mm Simplex cable
Refractive Index Core
Cladding
n 1.492
1.412
Mass per Unit Length/Channel 5.2 g/m 10
Cable Leakage Current IL <5x10
-5
nA 1KV,
l=0.11meters
Optical Characteristics, T
A
= -40°C to +85°C unless otherwise specied
Parameter Symbol Min. Typ.
[12]
Max. Unit Note
Cable Attenuation
Source: 660nm LED, 0.5 NA (HFBR-15xxZ)
α
O
0.15 0.19 0.23 dB/m
Reference attenuation
Source: 650nm monochromatic, 0.15NA
α
R
0.15 0.19 dB/m
Propagation Delay Constant l/v 5.0 ns/m 11
Notes:
1. Installation temperature is the range over which the cable can be bent and pulled without damage. Below -20°C the cable becomes brittle and
should not be subjected to mechanical stress.
2. Short term: 30mins.
3. Fail criteria for tensile force test: elongation higher than 5% of original length.
4. Bend angle is 90°. Bend radius is the radius of the mandrel around which the cable is bent.
5. Fail criteria for bend radius test: increase in attenuation higher than 0.5dB.
6. Long term: 24hours.
7. Bend angle is ±90°. Bend radius is the radius of the mandrel around which the cable is bent.
8. Fail criteria for exing test: increase in attenuation higher than 0.5dB.
9. Fiber length longer than 2 meters.
10. Without connectors
11. Propagation delay constant is the reciprocal of the group velocity for propagation delay of optical power. Group velocity is v=c/n, where c is the
velocity of light in free space (3x10
8
m/s) and n is the eective core index of refraction.