Description SR2
4/22 DocID026047 Rev 2
Figure 1. Logic diagram
Figure 2. Pin connections (top view)
SR2
RST
GND
V
CC
SR
0
SR1
GAMS2602141440SG
1
2
34
5
6
SR2
V
SS
NC
V
CC
SR 0
RST
SR 1
GAMS2602141445SG
DocID026047 Rev 2 5/22
SR2 Description
22
Figure 3. Block diagram
Table 1. Signal names
Pin Name Type Description
1 V
SS
Supply ground Ground
2 SR1
Input Secondary push-button Smart Reset™ input. Active low. Optional pull-up resistor
3 RST
Output
Reset output
(open drain with optional pull-up resistor, active low)
(push-pull – active low or active high)
4 NC - Not connected (not bonded; should be connected to V
SS
)
5 SR0
Input Primary push-button Smart Reset™ input. Active low. Optional pull-up resistor
6 V
CC
Supply voltage
Positive supply voltage for the device. A 0.1 µF decoupling ceramic capacitor is
recommended to be connected between V
CC
and V
SS
pins, as close to the SR2
device as possible
W
65&
JHQHUDWRU
W
5(&
JHQHUDWRU
RSWLRQDO
567
$1'
2YHUYROWDJHGHWHFW
 WHVWPRGHWULJJHU
65
65
$09
Pin descriptions SR2
6/22 DocID026047 Rev 2
2 Pin descriptions
2.1 Power supply (V
CC
)
This pin is used to provide power to the Smart Reset™ device. A 0.1 µF ceramic decoupling
capacitor is recommended to be connected between the V
CC
and V
SS
pins, as close to the
SR2 device as possible.
2.2 Ground (V
SS
)
Ground pin for the device.
2.3 Smart Reset™ input (SR0)
Push-button Smart Reset™ input is active low with optional pull-up resistor. Both SR
inputs need to be asserted simultaneously for at least t
SRC
to assert the reset output (RST).
By connecting a voltage higher than V
CC
to the SR0 the device enters a test mode (see
Section 1: Description on page 3 for more information).
2.4 Smart Reset™ input (SR1)
Push-button Smart Reset™ input is active low with optional pull-up resistor. Both SR inputs
need to be asserted simultaneously for at least t
SRC
to assert the reset output (RST).
2.5 Reset output (RST)
RST is active low or active high, push-pull or open drain reset output with optional internal
pull-up resistor. Output reset pulse width is optional as follows:
Neither fixed nor minimum output reset pulse duration (releasing the push-button while
reset output is active, causes the output to deassert);
Fixed, factory-programmed output reset pulse duration for t
REC
independent on Smart
Reset™ input state.
If V
CC
drops below 1.575 V, the RST output is deasserted and its state is guaranteed down
to 1 V (see Figure 8).