Characteristics STTH8R06
2/16 DocID7688 Rev 8
1 Characteristics
To evaluate the conduction losses use the following equation: P = 1.16 x I
F(AV)
+ 0.08 I
F
2
(RMS)
Table 2. Absolute ratings (limiting values at 25 °C unless otherwise specified)
Symbol Parameter Value Unit
V
RRM
Repetitive peak reverse voltage 600 V
I
F(RMS)
Forward current rms
TO-220AC / TO-220FPAC / D
2
PAK 30
A
TO-220AC ins. 24
I
F(AV)
Average forward
current δ = 0.5,
square wave
TO-220AC / D
2
PAK T
c
= 130 °C
8ATO-220FPAC T
c
= 85 °C
TO-220AC ins. T
c
= 100 °C
I
FSM
Surge non repetitive forward current t
p
= 10 ms sinusoidal 80 A
T
stg
Storage temperature range -65 to + 175 °C
T
j
Maximum operating junction temperature 175 °C
Table 3. Thermal resistance
Symbol Parameter Value (max) Unit
R
th(j-c)
Junction to case
TO-220AC / D
2
PAK 2.2
°C/WTO-220FPAC 4.6
TO-220AC ins. 3.8
Table 4. Static electrical characteristics
Symbol Parameter Test conditions Min. Typ. Max. Unit
I
R
Reverse leakage current
T
j
= 25 °C
V
R
= V
RRM
30
µA
T
j
= 125 °C 35 400
V
F
Forward voltage drop
T
j
= 25 °C
I
F
= 8 A
2.9
V
T
j
= 125 °C 1.4 1.8