DC and AC parameters M48T512Y, M48T512V
16/23 Doc ID 5747 Rev 7
5 DC and AC parameters
This section summarizes the operating and measurement conditions, as well as the DC and
AC characteristics of the device. The parameters in the following DC and AC Characteristic
tables are derived from tests performed under the measurement conditions listed in the
relevant tables. Designers should check that the operating conditions in their projects match
the measurement conditions when using the quoted parameters.
Table 7. Operating and AC measurement conditions
Figure 10. AC measurement load circuit
1. C
L
= 50 pF for M48T512V.
Table 8. Capacitance
Parameter M48T512Y M48T512V Unit
Supply voltage (V
CC
) 4.5 to 5.5 3.0 to 3.6 V
Ambient operating temperature (T
A
) 0 to 70 0 to 70 °C
Load capacitance (C
L
) 100 50 pF
Input rise and fall times ≤ 5 ≤ 5ns
Input pulse voltages 0 to 3 0 to 3 V
Input and output timing ref. voltages 1.5 1.5 V
Symbol Parameter
(1)(2)
1. Effective capacitance measured with power supply at 5 V (M48T512Y) or 3.3 V (M48T512V). Sampled
only, not 100% tested.
2. At 25 °C, f = 1 MHz.
Min Max Unit
C
IN
Input capacitance - 20 pF
C
IO
(3)
3. Outputs deselected.
Input / output capacitance - 20 pF
AI03971
C
L
(1)
C
L
includes JIG capacitance
DEVICE
UNDER
TEST
1.75V
650Ω
Obsolete Product(s) - Obsolete Product(s)