The current rating listed in the catalog indicates the allowable current per contact. However, in applications
requiring current transmission through all the contacts, about one-third of the listed rating should be applied.
When the current rating for the connector is 3 A, and the allowable current of the conductor being used is
1 A, then rating of 1 A will be used for the entire assembly.
The connectors should not be mating / unmating when the electrical current is being applied.
Hot swap should not be performed.
■Usage Environment
Please contact us about use in equipment that is subjected to repetitive high temperature and low
temperature environmental conditions.
The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information.