I
NTEGRATED
C
IRCUITS
D
IVISION
www.ixysic.com
2
R02
LCA100
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at conditions
beyond those indicated in the operational sections of this
data sheet is not implied.
Absolute Maximum Ratings @ 25˚ C
Parameter Ratings Units
Blocking Voltage 350 V
P
Reverse Input Voltage 5 V
Input Control Current
Peak (10ms)
50 mA
1A
Input Power Dissipation
1
150 mW
Total Power Dissipation
2
800 mW
Isolation Voltage, Input to Output 3750 V
rms
Operational Temperature -40 to +85 °C
Storage Temperature -40 to +125 °C
1
Derate linearly 1.33 mW / ºC
2
Derate linearly 6.67 mW / ºC
Parameter Conditions Symbol Min Typ Max Units
Output Characteristics
Load Current
AC/DC Confi guration, Continuous
1
-I
L
- - 120 mA
rms
& mA
DC
DC Confi guration, Continuous
1
-I
L
- - 200 mA
DC
Peak 10ms I
LPK
- - 350 mA
P
On-Resistance
2
AC/DC Confi guration I
L
=120mA
R
ON
--25
DC Confi guration I
L
=200mA - - 8
Off-State Leakage Current V
L
=350V I
LEAK
--1 µA
Switching Speeds
Turn-On
I
F
= 5mA, V
L
= 10V
t
on
--5 ms
Turn-Off t
off
--5 ms
Output Capacitance 50V, f=1MHz C
OUT
-35 - pF
Input Characteristics
Input Control Current to Activate I
L
= 120mA I
F
--5 mA
Input Control Current to Deactivate - I
F
0.4 0.7 - mA
Input Voltage Drop I
F
= 5mA V
F
0.9 1.2 1.4 V
Reverse Input Current V
R
= 5V I
R
- - 10 µA
Common Characteristics
Capacitance, Input to Output - C
I/O
-3 - pF
1
If both poles operate, then the load current must be derated so that the package power dissipation value is not exceeded.
2
Measurement taken within 1 second of on-time.
Electrical Characteristics @ 25ºC