SPECIFICATION
RSD-60 series
MODEL
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
EFFICIENCY (Typ.)
INPUT
INRUSH CURRENT (Typ.)
SAFETY STANDARDS
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSION
OTHERS
NOTE
PACKING
OVERLOAD
OVER VOLTAGE
DC CURRENT (Typ.)
105 ~ 135% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
-40 ~ +55 (no derating) ; +70 @ 60% load by free air convection ; +70 (no derating with external base plate)℃℃ ℃
5 ~ 95% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH℃
non-condensing
±℃ ℃0.03%/ (0 ~ 50 )
10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes ; Mounting : compliance to IEC61373
593.8K hrs min. MIL-HDBK-217F (25 )℃
128*60*25mm (L*W*H)
0.29Kg; 48pcs/14.9Kg/0.76CUFT
RIPPLE & NOISE (max.) Note.2
VOLTAGE TOLERANCE Note.3
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
ENVIRONMENT
PROTECTION
1. All parameters NOT specially mentioned are measured at 24,48VDC input, rated load and 25 of ambient temperature.℃
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on
a mm* mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives.360 360 For guidance on how to
perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com)
5. Strongly recommended that external output capacitance should not exceed 5000uF.
6. The ambient temperature derating of 3.5 /1000m with fanless models and of 5 /1000m with fan models for operating altitude higher than 2000m(6500ft).℃℃
3.3V 5V 12V 24V 5V 12V 24V
RSD-60G-3.3 RSD-60G-5 RSD-60G-12 RSD-60G-24 RSD-60L-5 RSD-60L-12 RSD-60L-24
12A 12A 12A5A 5A2.5A 2.5A
0 ~ 12A 0 ~ 12A 0 ~ 12A0 ~ 5A 0 ~ 5A0 ~ 2.5A 0 ~ 2.5A
39.6W 60W 60W60W 60W
60mVp-p 100mVp-p 60mVp-p50mVp-p 50mVp-p50mVp-p 50mVp-p
±2.0% ±2.0% ±2.0%±2.0% ±2.0%±2.0% ±2.0%
±0.5% ±0.5% ±0.5%±0.3% ±0.3%±0.2% ±0.2%
±0.5% ±0.5% ±0.5%±0.3% ±0.3%±0.2% ±0.2%
100ms, 60ms at full load
9 ~ 36VDC
86.5% 88%
2.1A/24VDC 3A/24VDC
92% 90% 89% 93% 91.5%
1.5A/48VDC
20A/48VDC
20A/24VDC
4.3 ~ 4.95V 5.75 ~ 7V 5.75 ~ 7V13.8 ~ 16.2V 13.8 ~ 16.2V27.6 ~ 32.4V 27.6 ~ 32.4V
HOLD UP TIME (Typ.)
G type comply with S1 level(3ms) full load,S2 level(10ms) @50% load S2 10@ ; L type comply with level( ) @full load
ms
Protection type : Shut down o/p voltage, re-power on to recover
VOLTAGE RANGE CONTINUOUS
I/P-O/P:4KVDC I/P-FG:2.5KVDC O/P-FG:2.5KVDC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH℃
EAC TP TC 004 approved, IEC60950-1 (LVD)
60W 60W
3.3V
RSD-60L-3.3
12A
0 ~ 12A
39.6W
60mVp-p
±2.0%
±0.5%
±0.5%
88.5%
18 ~ 72VDC
0.95A/48VDC
4.3 ~ 4.95V
60W Reliable Railway DC-DC Converter
SAFETY &
EMC
(Note 4)
EMC IMMUNITY
EMC EMISSION
RAILWAY STANDARD
Compliance to ; EN50155 / IEC60571 including IEC61373 for shock & vibration, EN50121-3-2 for EMCEN45545-2 for fire protection
Parameter
Parameter
Standard
Standard
Test Level / Note
Test Level / Note
Radiated
Conducted
Harmonic Current
Voltage Flicker
EN55032
EN55032
EN6100-3-2
EN6100-3-3
Class A
Class B
Class A
-----
ESD
Radiated Field
EFT / Burst
Surge
Conducted
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
Level X
Level 3, 8KV air ; Level 3, 6KV contact±±
Level 3, 2KV at power
Level 4, 2KV at signal
Level 3
Level 3,1KV Line-Line, Level 3, 2KV Line-Earth
File Name:RSD-60-SPEC 2018-01-12