Rev.12.17.07
bxa30
3 of 5
Embedded Power for
Business-Critical Continuity
Ordering Information
Notes
1 Nominal, at no load.
2 Low line to high line.
3 Full load to no-load. For duals, the value stated is for balanced loads.
4 An optional internal filter is available, which will meet VDE0871 level A,
VDE0878 level A and EN55022 level A. Add the suffix ‘-F’ to the model number,
e.g. BXA30-48S12-FJ. See BXA15 and BXA30 Design Note 100.
5 For conducted noise operation of the BXA30 to VDE0871, VDE0878 and
EN55022 level B, see BXA15 and BXA30 Design Note 100.
6 For extended operating temperature, include the heatsink option, ‘-1’ in the
model number. Max. heatsink height is 12.5 mm, e.g. BXA30-48S15-1J
7 Reverse voltage protection can be implemented by putting a slow blow fuse on
the negative input rail. Rate the fuse for 48 Vdc at 1.5 A and 12 Vdc at 6 A.
8 The maximum operating ambient temperature, without derating depends on
internal power dissipation and hence efficiency and cooling method. BXA15
and BXA30 Design Note 100 provides detailed thermal calculations and design-
in details.
9 Test results to-date are 1,590,000 hours @ 46 ˚C. The MTBF figure shown
includes a calculated acceleration factor of 4.1 based on an activation energy of
-0.55 eV.
10 Visit the Artesyn website to download a copy of Design Note 100.
11 This model has the same electrical pin-out and pin pitch spacings as the
drawing on the following page. Dimensions are 76.2 x 76.2 x 14.2 mm,
±0.3
mm.
12 This product is only for inclusion by professional installers within other
equipment and must not be operated as a stand alone product.
13 If remote sense is not used, connect +sense to +vout and -sense to -vout.
14 The ‘J’ suffix indicates that these parts are Pb-free (RoHS 6/6) compliant.
TSE RoHS 5/6 (non Pb-free) compliant versions may be available on special
request, please contact your local sales representative for details.
15 NOTICE: Some models do not support all options. Please contact your local
Artesyn representative or go to www.powerconversion.com to find a suitable
alternative
INPUT OUTPUT OUTPUT INPUT TYPICAL REGULATION MODEL
VOLTAGE VOLTAGE CURRENT (MAX.) CURRENT
(1)
EFFICIENCY LINE
(2)
LOAD
(3)
NUMBER
(4,6,14,15)
9-18 Vdc 5.0 V 5.0 A 100 mA 80% ±0.2% ±0.2% BXA30-12S05J
36-75 Vdc 3.3 V 6.0 A 30 mA 75% ±0.2% ±0.2% BXA30-48S3V3J
36-75 Vdc 3.3 V 8.0 A 30 mA 81% ±0.2% ±0.2% BXA30-48S3V3/8J
(11)
36-75 Vdc 5.0 V 5.0 A 30 mA 80% ±0.4% ±1.0% BXA30-48S05J
36-75 Vdc 12.0 V 2.5 A 30 mA 85% ±0.2% ±0.2% BXA30-48S12J
36-75 Vdc 15.0 V 2.0 A 30 mA 87% ±0.2% ±0.2% BXA30-48S15J
36-75 Vdc ±5.0 V ±2.5 A 30 mA 80% ±0.4% ±0.4% BXA30-48D05J
36-75 Vdc ±12.0 V ±1.25 A 30 mA 84% ±0.4% ±0.4% BXA30-48D12J
36-75 Vdc ±15.0 V ±1.0 A 30 mA 86% ±0.4% ±0.4% BXA30-48D15J