SPECIFICATIONS
COMPACT POWER RELAYS
JC RELAYS
VDE
TM type
FEATURES
• High inrush current capability
1 Form A: 163 A inrush (TV-8)
2 Form A: 111 A inrush (TV-5)
• High dielectric withstanding for transient protection:
JC can withstand 10,000 V surge in µs between coil and
contact.
• Electrical life:
1 Form A: 10
5
ope. at 15 A 250 V AC resistive load
2 Form A: 10
5
ope.
at 10 A 250 V AC resistive load
• UL/CSA, VDE, TÜV, SEMKO also approved.
COMMENTS ABOUT Cd FREE
We have introduced Cadmium free type products to reduce the
material which is not good for our environment. (The suffix “F”
should be added to the part number.) If you are still using
Cadmium containing parts, which don’t have “F” on the suffix of
the part number, please use Cadmium free parts from now on.
The life of the Cadmium free parts may be shorter than the
Cadmium containing parts based on the load condition, so
please evaluate the Cadmium free parts with your actual
application before use.
PC board type
Plug-in type
30.4
1.197
30.0
1.181
19.0
.748
32.4
1.276
30.0
1.181
19.0
.748
32.9
1.295
45.0
1.772
19.0
.748
mm inch
RoHS Directive compatibility information
http://www.nais-e.com/
Contact
Coil
#1 This value can change due to the switching frequency, environmental conditions,
and desired reliability level, therefore it is recommended to check this with the
actual load.
Remarks
* Specifications will vary with foreign standards certification ratings.
*
1
Measurement of same location as “Initial breakdown voltage” section
*
2
Detection current: 10mA
*
3
Excluding contact bounce time
*
4
Half-wave pulse of sine wave: 11ms; detection time: 10µs
*
5
Half-wave pulse of sine wave: 6ms
*
6
Detection time: 10µs
*
7
Refer to 6. Conditions for operation, transport and storage mentioned in
AMBIENT ENVIRONMENT
Characteristics
Arrangement 1 Form A 2 Form A
Initial contact resistance, max.
(By voltage drop 6 V DC 1 A)
30 mΩ
Contact material AgSnO2 type
Contact force, min. 30 g
Rating
(resistive
load)
Maximum switching power 3,750 VA 2,500 VA
Maximum switching voltage
250 V AC 250 V AC
Max. switching current 15 A 10 A
Min. switching capacity
#1
100 mA, 5 V DC
Expected
life (min.
operation)
Mechanical 5×10
6
Electrical
(resistive)
10 A 250 V AC 10
5
—
5A 250 V AC — 10
5
Nominal operating power 900 mW 1,000 mW
Maximum operating speed 20 cpm.
Initial insulation resistance*
1
Min. 100 MΩ at 500 V DC
Initial
breakdown
voltage*
2
Between open contacts 2,000 V rms for 1 min.
Between contacts sets 2,000 Vrms for 1 min.
Between contacts and
coil
4,000 Vrms for 1 min.
Operate time*
3
(at nominal voltage)
Max. 30 ms
Release time(without diode)*
3
(at nominal voltage)
Max. 10 ms
Temperature rise
(at nominal voltage)
Max. 55°C
Shock
resistance
Functional*
4
196 m/s
2
{20 G}
Destructive*
5
980 m/s
2
{100 G}
Vibration
resistance
Functional*
6
98 m/s
2
{10 G}, 10 to 55 Hz
at double amplitude of 1.6 mm
Destructive
117.6 m/s
2
{12 G}, 10 to 55 Hz
at double amplitude of 2 mm
Conditions for operation,
transport and storage*
7
(Not freezing and condens-
ing at low temperature)
Ambient
temp.
–50°C to +60°C
–58°F to +140°F
Humidity 5 to 85%R.H.
Unit weight Approx. 31 g 1.09 oz