DG411/412/413
Vishay Siliconix
www.vishay.com S FaxBack 408-970-5600
4-4
Document Number: 70050
S-52433—Rev. D, 06-Sep-99
Test Conditions
Unless Specified
A Suffix
–55 to 125_C
D Suffix
–40 to 85_C
Parameter Symbol
V+ = 12 V, V– = 0 V
V
L
= 5 V, V
IN
= 2.4 V, 0.8 V
f
Temp
b
Typ
c
Min
d
Max
d
Min
d
Max
d
Unit
Analog Switch
Analog Signal Range
e
V
ANALOG
Full 12 12 V
Drain-Source
On-Resistance
r
DS(on)
V+ = 10.8 V, I
S
= –10 mA
V
D
= 3 V, 8 V
Room
Full
40 80
100
80
100
W
Dynamic Characteristics
Turn-On Time t
ON
R
L
= 300 W , C
L
= 35 pF
Room
Hot
175 250
400
250
315
Turn-Off Time t
OFF
V
S
= 8 V, See Figure 2
Room
Hot
95 125
140
125
140
ns
Break-Before-Make
Time Delay
t
D
DG413 Only, V
S
= 8 V,
R
L
= 300 W , C
L
= 35 pF
Room 25
Charge Injection Q V
g
= 6 V, R
g
= 0 W , C
L
= 10 nF Room 25 pC
Power Supplies
Positive Supply Current I+
Room
Hot
0.0001 1
5
1
5
Negative Supply Current I–
=
=
Room
Hot
–0.0001 –1
–5
–1
–5
Logic Supply Current I
L
=
.
,
IN
=
Room
Hot
0.0001 1
5
1
5
m
Ground Current I
GND
Room
Hot
–0.0001 –1
–5
–1
–5
Notes:
a. Refer to PROCESS OPTION FLOWCHART.
b. Room = 25_C, Full = as determined by the operating temperature suffix.
c. Typical values are for DESIGN AID ONLY, not guaranteed nor subject to production testing.
d. The algebraic convention whereby the most negative value is a minimum and the most positive a maximum, is used in this data sheet.
e. Guaranteed by design, not subject to production test.
f. V
IN
= input voltage to perform proper function.
_
On-Resistance vs. V
D
and Power Supply Voltage
V
D
– Drain Voltage (V)
–20 –15 –10 –5 0 5 10 15 20
45
40
35
30
25
20
15
10
5
0
T
A
= 25_C
50
5 V
8 V
10 V
12 V
15 V
20 V
r
DS(on)
– Drain-Source On-Resistance (
0 2 4 6 8 10 12 14 16 18 20
0
50
100
150
200
250
300
(
DS(on)
V
V
L
= 5 V
On-Resistance vs. V
D
and Unipolar Supply Voltage
V+ = 3 V
V
L
= 3 V
8 V
V+ = 5 V
12 V
15 V
20 V
V
D
– Drain Voltage (V)
)W
W
)