3 07/12
Please read Cautions and warnings and
Important notes at the end of this document.
Dimensional drawing and pin configuration
Technical data and measuring conditions
Rated voltage V
R
300 V AC (50/60 Hz)
The use of the parallel windings with different voltages is
not permissible!
Test voltage V
test
1500 V AC / 2100 V DC, 2 s (line/line)
500 V DC, 2 s (parallel wires)
Rated temperature T
R
+75 C
Rated current I
R
Referred to 50 Hz and rated temperature
(parallel windings connected in customer circuit)
Rated inductance L
R
Measured with Agilent 4284A at 100 kHz, 0.1 mA,
+20 °C Inductance is specified per winding.
Inductance tolerance –30/+50% at +20 °C
Inductance decreaseL/L
0
< 10% at DC magnetic bias with I
R
, +20 °C
Stray inductance L
stray,typ
Measured with Agilent 4284A at 100 kHz, 5 mA, +20 °C,
typical value
DC resistance R
typ
Measured at +20 °C, typical value, specified per winding
Solderability (lead-free) Sn96.5Ag3.0Cu0.5: +(245 5) °C, (3 0.3) s
Wetting of soldering area 95%
(to IEC 60068-2-20, test Ta)
IND0798-R-E
67
23
12 43
6785
8
1
5
4
4+1
A
30
20
Marking
55 max.
24
ø2.5±0.1
ø1
8x
A
50 max.
34 max.
B82726S3543N040Power line chokes
Current-compensated ring core double chokes