82A0811-4-9CS3193

Users should evaluate the suitability of this product for their application. Speci cations are subject to change without notice.
Tyco Electronics Corporation also reserves the right to make changes in materials or processing, which do not affect compliance with any speci cation, without noti cation to Buyer.
1/ COLORS AND COLOR CODE DESIGNATORS SHALL BE IN ACCORDANCE WITH MIL-STD-681. OTHER CODES AND SUFFIXES MAY BE
ADDED TO THE PART NUMBER, AS NECESSARY, TO CAPTURE ANY ADDITIONAL REQUIREMENTS IMPOSED BY THE PURCHASE ORDER.
Page 1 of 2
Raychem, TE Connectivity, TE connectivity (logo), and TE (logo) are trademarks.
Raychem Wire & Cable
501 Oakside Avenue
Redwood City, CA 94063-3800
Phone: 1-800-227-8816
Fax: 1-650-361-6297
DIMENSIONS ARE IN INCHES AND, UNLESS OTHERWISE DESIGNATED, ARE NOMINAL.
THIS SPECIFICATION SHEET TAKES PRECEDENCE OVER DOCUMENTS REFERENCED HEREIN.
REFERENCED DOCUMENTS SHALL BE OF THE ISSUE IN EFFECT ON DATE OF INVITATION FOR BID.
© 2013 Tyco Electronics Corporation. All rights reserved.
TABLE I. CONSTRUCTION DETAILS
PART NUMBER
1/
WIRE
SIZE
(AWG)
CONDUCTOR
STRANDING
(number x AWG)
DIAMETER OF
STRANDED
CONDUCTOR
(inch)
FINISHED WIRE
MAXIMUM
RESISTANCE
AT 20°C
(ohms/1000 ft.)
DIAMETER
(inch)
MAXIMUM
WEIGHT
(lbs/1000 ft.)
MINIMUM MAXIMUM
82A0811-24-* 24 105 x 44 .023 .027 28.2 .044 ± .003 2.5
82A0811-22-* 22 154 x 44 .029 .033 19.2 .054 ± .003 3.7
82A0811-20-* 20 154 x 42 .037 .043 11.7 .064 ± .004 5.2
82A0811-18-* 18 259 x 42 .047 .053 7.14 .076 ± .004 8.0
82A0811-16-* 16 259 x 40 .061 .067 4.53 .092 ± .005 11.9
82A0811-14-* 14 665 x 42 .078 .086 2.96 .116 ± .005 19.3
82A0811-12-* 12 665 x 40 .096 .106 1.89 .137 ± .006 27.9
82A0811-10-* 10 665 x 38 .126 .140 1.12 .187 ± .008 50.0
82A0811-8-* 8 665 x 36 .157 .173 .714 .230 ± .008 77.3
82A0811-6-* 6 1045 x 36 .192 .208 .490 .277 ± .010 118.
82A0811-4-* 4 1665 x 36 .265 .285 .326 .359 ± .010 189.
82A0811-2-* 2 1665 x 34 .325 .345 .204 .433 ± .016 282.
82A0811-1-* 1 2109 x 34 .370 .400 .163 .488 ± .016 348.
82A0811-0-* 0 2660 x 34 .435 .465 .133 .558 ± .016 442.
82A0811-00-* 00 3325 x 34 .485 .515 .102 .612 ± .016 544.
82A0811-000-* 000 4123 x 34 .540 .575 .087 .678 ± .016 668.
82A0811-0000-* 0000 5320 x 34 .615 .655 .066 .771 ± .022 863.
CONDUCTOR - TIN-COATED COPPER
SPECIFICATION CONTROL DRAWING
82A0811
WIRE, RADIATION-CROSSLINKED, MODIFIED FLEXIBLE ETFE-INSULATED,
NORMAL WEIGHT, GENERAL PURPOSE, 600 VOLT
11-5-13 F
This speci cation sheet forms a part of the latest issue of Raychem Speci cation 80.
TITLE
Date Revision
PRIMARY INSULATION - RADIATION-CROSSLINKED,
MODIFIED FLEXIBLE ETFE
COLOR - LIGHT GREEN
JACKET - RADIATION-CROSSLINKED,
MODIFIED FLEXIBLE ETFE
SPECIFICATION CONTROL DRAWING
82A0811
2 of 2 F
Page Revision
TABLE II. PERFORMANCE DETAILS
PART NUMBER
1/
BEND TESTING
MANDREL DIAMETER
(inch) (± 3%)
WEIGHT
(lbs) (± 3%)
CROSSLINKING PROOF TEST CROSSLINKING PROOF TEST
82A0811-24-* .500 .750
82A0811-22-* .500 1.00
82A0811-20-* .500 1.50
82A0811-18-* .750 2.00
82A0811-16-* 1.00 2.00
82A0811-14-* 1.00 3.00
82A0811-12-* 1.50 3.00
82A0811-10-* 2.00 3.00
82A0811-8-* 3.00 4.00
82A0811-6-* 4.00 4.00
82A0811-4-* 5.00 4.00
82A0811-2-* 6.00 6.00
82A0811-1-* 8.00 6.00
82A0811-0-* 8.00 6.00
82A0811-00-* 10.0 8.00
82A0811-000-* 10.0 8.00
82A0811-0000-* 10.0 8.00
WIRE RATINGS AND ADDITIONAL REQUIREMENTS
TEMPERATURE RATING: 150°C
Maximum continuous conductor temperature
VOLTAGE RATING: 600 volts (rms) at sea level
CONCENTRICITY: 70% (minimum)
CROSSLINKING PROOF TEST: 300 ± 3°C for 7 hours
IDENTIFICATION AND COLOR STRIPING DURABILITY:
125 cycles (250 strokes) (minimum), 500 g weight
INSULATION ELONGATION AND TENSILE STRENGTH:
AWG 24-10: Elongation, 75% (minimum)
Tensile Strength, 3500 lbf/in² (minimum)
AWG 8-0000: Elongation, 125% (minimum)
Tensile Strength, 3000 lbf/in² (minimum)
INSULATION FLAWS:
Primary Insulation,
Spark Test, 1.5 kV (rms) at 3 kHz
Impulse Dielectric Test, 6.0 kV (peak)
Finished Wire,
Spark Test, 3.0 kV (rms) at 3 kHz
Impulse Dielectric Test, 8.0 kV (peak)
1/ See footer section on page 1
INSULATION THICKNESS:
AWG 24-18: .004 in. (minimum) for primary insulation
.004 in. (minimum) for outer jacket
AWG 16-10: .005 in. (minimum) for primary insulation
.005 in. (minimum) for outer jacket
AWG 8-4: .008 in. (minimum) for primary insulation
.012 in. (minimum) for outer jacket
AWG 2-0000: .010 in. (minimum) for primary insulation
.015 in. (minimum) for outer jacket
JACKET COLOR: White preferred
SECANT MODULUS (Test per ASTM D 882):
AWG 24-10: 5.0 x 10
4
lbf/in
2
(maximum)
AWG 8-0000: 4.0 x 10
4
lbf/in
2
(maximum)
2% strain, 2 inch jaw separation, 0.2 inch/minute
SHRINKAGE: 150 ± 3°C for 6 hours,
AWG 24-10: 0.13 in. (maximum) in 12 inches
AWG 8-0000: 0.25 in. (maximum) in 12 inches
VOLTAGE WITHSTAND (Post Environmental): 2500 volts (rms), 60 Hz
1/ PART NUMBER:
The “*” in the part numbers on pages 1 and 2 shall be replaced by a
color code designator.
Example: AWG 12, white: 82A0811-12-9
AWG 12, white with a black stripe: 82A0811-12-90

82A0811-4-9CS3193

Mfr. #:
Manufacturer:
TE Connectivity
Description:
Hook-up Wire 82A0811-4-9CS3193
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS