MK02/6-1

A Global Leader in the Design, Development, and
Manufacture of Sensor and Magnetic Components
Series Datasheet MK02/6 Reed Sensors
www.standexmeder.com
MK02/6 Series
Reed Sensors
Features: Ferrous Metal Detection, Front or Above Operation, THT
Applications: Door & Window Control, Fire Protection Doors, Safety & Interlock Sensing & Others
Markets: Industrial, Security & Others
Modifications in the sense of technical progress are reserved.
Part
Description: MK 02/ 6 - 0
Operation Series Contact QTY
6 01
Customer
Options
Switch Model
Unit
Contact Data
80
Rated Power
(max.)
Any
DC combination of V&A not to exceed their individual max.’s
10 W
Switching Voltage
(max.)
DC or
peak AC
170 V
Switching Current
(max.)
DC
or peak AC
0.5 A
Carry Current
(max.)
DC
or peak AC
0.5 A
Contact Resistance
(max.)
@
0.5V & 50mA
200 mOhm
Breakdown
Voltage (min.)
According
to EN60255-5
0.21 kVDC
Operating
Time (max.)
Incl. Bounce; Measured with w/ Nominal Voltage
0.6 ms
Release Time (max.)
Measured
with no Coil Excitation
0.05 ms
Insulation
Resistance (typ.)
Rh<45
%, 100V Test Voltage
10
9
GOhm
Capacitance
(typ.)
@
10kHz across open Switch
0.4 pF
Version 01
27.01.2015
USA: +1.866.782.6339 salesusa@standexmeder.com
Europe: +49.7731.8399.0 │ info@standexmeder.com
Asia: +86.21.37820625 │ salesasia@standexmeder.com
MK02/6
Reed Sensor
A Global Leader in the Design, Development, and
Manufacture of Sensor and Magnetic Components
Series Datasheet MK02/6 Reed Sensors
www.standexmeder.com
Environmental
Data Unit
Shock Resistance (max.)
1/2 sine wave duration 11ms
50 g
Vibration
Resistance (max.)
20 g
Operating Temperature
-20 to 80 °C
Storage Temperature
-20 to 80
°C
Housing and Cable
Specifications
Housing
Material
PBT Glass
Fibre Reinforced
Case
Color
Black
Sealing
Compound
Polyurethan
Glossary Contact Form
Form
A
Throw
Form B
Contacts
= Single Pole Single Throw
Form C
Throw
Modifications in the sense of technical progress are reserved.
Version 01
27.01.2015
USA: +1.866.782.6339 salesusa@standexmeder.com
Europe: +49.7731.8399.0 │ info@standexmeder.com
Asia: +86.21.37820625 │ salesasia@standexmeder.com
Life Test Data
*Load increase reduces life
expectancy of Reed Switches
Handling
& Assembly Instructions
Use proper lead clamping/heat sinking techniques to prevent
mechanical and/or heat stress during soldering & welding
Mechanical shock as the result of dropping the reed sensor
may cause immediate or post-installation failure
Only a simple piece of iron is required to activate switching
position
Operation Series
PCB Through Hole Mount
A Global Leader in the Design, Development, and
Manufacture of Sensor and Magnetic Components
Series Datasheet MK02/6 Reed Sensors
www.standexmeder.com
Modifications in the sense of technical progress are reserved.
Version 01
27.01.2015
USA: +1.866.782.6339 salesusa@standexmeder.com
Europe: +49.7731.8399.0 │ info@standexmeder.com
Asia: +86.21.37820625 │ salesasia@standexmeder.com
For best operation it is recommended that you DO NOT mount these sensors on any ferromagnetic material OR use any
ferromagnetic screws.

MK02/6-1

Mfr. #:
Manufacturer:
Description:
Proximity Sensors Mtl Dt Reed Sens PCB Top Actn 24mm Len
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet