A7CN/A7CN-L
2
End Caps
End Caps are used on the Switch Units at each end and allow all the Switch Units to be securely mounted to a panel. They come in pairs, one for
the left and one for the right.
Spacers
• Spacers are used for creating extra space or gaps between the Switch Units and have the same dimensions as the Switch Units themselves.
• There are also Spacers with engraved characters or symbols that can be used for indicating units, such as time and length. (Refer to the following
table.) Consult your OMRON representative for details.
Specifications
Symbol A B C D E F G
Stamp
No desig-
nation
SEC MIN H g kg mm
Symbol H J K L Q T U
Stamp cm m °CPCS
x10
SEC
0•
Switching capacity (resistive load)
3.3 to 28 VDC
1 mA to 0.1 A
Continuous carry current 1A
Contact resistance 200 mΩ max.
Insulation
resistance
Between non-connected
terminals
10 MΩ min. (at 250 VDC)
Between terminal and
non-current carrying part
100 MΩ min. (at 500 VDC)
Dielectric
strength
Between non-connected
terminals
200 VAC, 50/60 Hz for 1 min
Between terminal and
non-current carrying part
1,000 VAC, 50/60 Hz for 1 min
Vibration resistance 10 to 55 Hz, 1.5-mm double amplitude
Shock resistance 490m/s
2
min.
Durability
Mechanical 30,000 operations min.
Electrical 20,000 operations min.
Ambient temperature
Operating: -10°C to 65°C (with no icing)
Storage: -20°C to 80°C
Ambient humidity Operating: 35% to 85%
Max. operating force 4.41 N max.