MC10EP17, MC100EP17
www.onsemi.com
3
Table 3. MAXIMUM RATINGS
Symbol Parameter Condition 1 Condition 2 Rating Unit
V
CC
PECL Mode Power Supply V
EE
= 0 V 6 V
V
EE
NECL Mode Power Supply V
CC
= 0 V −6 V
V
I
PECL Mode Input Voltage
NECL Mode Input Voltage
V
EE
= 0 V
V
CC
= 0 V
V
I
v V
CC
V
I
w V
EE
6
−6
V
I
out
Output Current Continuous
Surge
50
100
mA
I
BB
V
BB
Sink/Source ± 0.5 mA
T
A
Operating Temperature Range −40 to +85 °C
T
stg
Storage Temperature Range −65 to +150 °C
q
JA
Thermal Resistance (Junction-to-Ambient) 0 lfpm
500 lfpm
TSSOP−20 WB 140
100
°C/W
q
JC
Thermal Resistance (Junction-to-Case) Standard Board TSSOP−20 WB 23 to 41 °C/W
q
JA
Thermal Resistance (Junction-to-Ambient) 0 lfpm
500 lfpm
SOIC−20 WB 90
60
°C/W
q
JC
Thermal Resistance (Junction-to-Case) Standard Board SOIC−20 WB 30 to 35 °C/W
q
JA
Thermal Resistance (Junction-to-Ambient) 0 lfpm
500 lfpm
QFN−20 47
33
°C/W
q
JC
Thermal Resistance (Junction-to-Case) Standard Board QFN−20 18 °C/W
T
sol
Wave Solder (Pb-Free) 265 °C
Stresses exceeding those listed in the Maximum Ratings table may damage the device. If any of these limits are exceeded, device functionality
should not be assumed, damage may occur and reliability may be affected.
Table 4. 10EP DC CHARACTERISTICS, PECL (V
CC
= 3.3 V, V
EE
= 0 V (Note 1))
Symbo
Characteristic
−40°C 25°C 85°C
Uni
Min Typ Max Min Typ Max Min Typ Max
I
EE
Power Supply Current 42 50 65 44 52 66 46 54 68 mA
V
OH
Output HIGH Voltage (Note 2) 2165 2290 2415 2230 2355 2480 2290 2415 2540 mV
V
OL
Output LOW Voltage (Note 2) 1365 1490 1615 1430 1555 1680 1490 1615 1740 mV
V
IH
Input HIGH Voltage (Single-Ended) 2090 2415 2155 2480 2215 2540 mV
V
IL
Input LOW Voltage (Single-Ended) 365 1690 1430 1755 1490 1815 mV
V
BB
Output Voltage Reference 1790 1890 1990 1855 1955 2055 1915 2015 2115 mV
V
IHCMR
Input HIGH Voltage Common Mode
Range (Differential) (Note 3)
2.0 3.3 2.0 3.3 2.0 3.3 V
I
IH
Input HIGH Current 150 150 150
mA
I
IL
Input LOW Current 0.5 0.5 0.5
mA
NOTE: Device will meet the specifications after thermal equilibrium has been established when mounted in a test socket or printed circuit
board with maintained transverse airflow greater than 500 lfpm. Electrical parameters are guaranteed only over the declared
operating temperature range. Functional operation of the device exceeding these conditions is not implied. Device specification limit
values are applied individually under normal operating conditions and not valid simultaneously.
1. Input and output parameters vary 1:1 with V
CC
. V
EE
can vary +0.3 V to −2.2 V.
2. All loading with 50 W to V
CC
− 2.0 V.
3. V
IHCMR
min varies 1:1 with V
EE
, V
IHCMR
max varies 1:1 with V
CC
. The V
IHCMR
range is referenced to the most positive side of the differential
input signal.