Recommended external circuit components
Vin (Vdc) 24 48
FUSE Choose according to input current
MOV S14K35 S14K60
LDM1 56H56H
TVS SMCJ48A SMCJ90A
C0 330F/50V 330F/100V
C1 1F/50V 1F/100V
LDM2 4.7H 4.7H
CY1 1 nF/2 KV 1 nF/2 KV
CY2 1 nF/2 KV 1 nF/2 KV
EMC RECOMMENDED CIRCUIT
DERATING CURVES
LDM2
C0
TVS
LDM1
MOV
FUSE
(a) (b)
C1
Vin
GND
+
Vin
GND
+Vo
-Vo
(0V)
EUT
LOAD
CY2
CY1
Figure 1
Figure 2
Table 2
Table 1
TEST CONFIGURATION
DC
Cin
Lin
DC
Load
Oscilloscope
Current
Probe
Note: Input re ected-ripple current is measured with an inductor Lin and Capacitor Cin to simulate source impedance.
External components
Lin 4.7H
Cin
220F, ESR < 1.0
at 100 KHz
100
80
60
40
20
Ambient Temperature (°C)
Load (%)
-40 -20 0 20 40 60
8571
Temperature Derating Curve
Safe operating area
For more information, please visit the product page.
cui.com
CUI Inc SERIES: PYB10-T & PYB10-U DESCRIPTION: DC-DC CONVERTER date 08/16/2013 page 5 of 6
1. Recommended circuit
This series has been tested according to the following recommended testing circuit before leaving the factory. This series should be
tested under load (see Figure 3). If you want to further decrease the input/output ripple, you can increase the capacitance accord-
ingly or choose capacitors with low ESR (see table 3). However, the capacitance of the output lter capacitor must be appropriate. If
the capacitance is too high, a startup problem might arise. For every channel of the output, to ensure safe and reliable operation, the
maximum capacitance must be less than the maximum capacitive load (see Table 4).
APPLICATION NOTES
Figure 3
Table 4Table 3
Vin
(Vdc)
Cin
(F)
Cout
(F)
24 10~47 10
48 10~47 10
Note: 1. Minimum load shouldn't be less than 5%, otherwise ripple may increase dramatically. Operation under minimum load will not damage the converter, however, they may
not meet all speci cations listed.
2. Maximum capacitive load is tested at input voltage range and full load.
3. All speci cations are measured at Ta=25°C, humidity<75%, nominal input voltage and rated output load unless otherwise speci ed.
Vin
GN D
+Vo
0V
DC
Cin
DC
Cout
Cout
-Vo
Dual Output
Single Output
Vin
GN D
+Vo
0V
DC
Cin
DC
Cout
Single
Vout
(Vdc)
Max.
Capacitive
Load
(F)
Dual
Vout
(Vdc)
Max.
Capacitive
Load
4
(F)
3.3 2200 -- --
5 2200 5 680
12 470
1
12 220
3
15 330
2
15 100
24 100 -- --
Notes: 1. 330 F for 48Vin.
2. 220 F for 48Vin.
3. 150 F for 48Vin.
4. For each output.
For more information, please visit the product page.
CUI Inc SERIES: PYB10-T & PYB10-U DESCRIPTION: DC-DC CONVERTER date 08/16/2013 page 6 of 6
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical
component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to
affect its safety or effectiveness.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
techsupport@cui.com
rev. description date
1.0 initial release 06/26/2013
1.01 updated spec 08/16/2013
The revision history provided is for informational purposes only and is believed to be accurate.
REVISION HISTORY
For more information, please visit the product page.

PYB10-Q24-S24-T

Mfr. #:
Manufacturer:
Description:
Isolated DC/DC Converters Isolated Chassis Mount DC-DC Cnvrt
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union