RST-10000-36

10000W Power Supply with Single Output
RST-10000 series
File Name:RST-10000-SPEC 2018-01-15
4.Select Overload Protection (OLP) Mode
(1)Continuous Constant Current mode
(2)Delay Shutdown mode
Have the DIP switch position-1 set as ,and RST-10000 will work in continuous constant current mode when the output is overloaded and
Have the DIP switch position-1 set as ,and RST-10000 will shut down after 5 seconds of constant current operation, when the output is
the output voltage is greater than 50% of the rated output voltage.
overloaded or short-circuited.
ON
OFF
123
ON
OFF
123
5.Remote ON-OFF Control
The power supply can be turned ON-OFF by using the "Remote ON-OFF" function.
Switch open (Open) power supply OFF
Between ( ) and 12V-AUX( )Remote ON-OFF CN992 or CN993 pin10 CN991 pin1
Switch close (Short)
Output Status
power supply ON
Table 5.1
Fig 5.1
PIN1 12V-AUX
PIN3 GND-AUX
PIN10 RC+
PIN8 RC-
6.Alarm Signal Output
There are 4 alarm signals on CN991, and each signal can select two types of output circuit.
(1)Relay contact output {OTP1, OTP1-GND) ; (DC-OK1, DC-OK1-GND) ; (AC-FAIL1-GND,AC-FAIL1) ; (FAN-FAIL1-GND, FAN-FAIL1)}
(2)Open collector output {DC-OK2-GND, DC-OK2) ; (AC-FAIL2-GND, AC-FAIL2) ; (OTP2, OTP2-GND) ; (FAN-FAIL2, FAN-FAIL2-GND)}
Normally open contact. "Short" when the alarm arises. Relay contact rating(maximum) is 30V/1Aresistive.
An external voltage source is required for this function that is shown in Fig 6.2. These signals are isolated from output. The maximum sink current is
10mA and the maximum external voltage is 20V (there is a built-in 24V zener diode in inner circuitry).
Fig 6.1
Fig 6.2
R
V
DC-OK2
GND-AUX
12V-AUX
RST-10000
DC-OK2-GND
AC-FAIL2
OTP2
FAN-FAIL2
AC-FAIL2-GND
OTP2-GND
FAN-FAIL2-GND
10KΩ x4pcs
Application
Circuit
DIP
SW
CN993
CN992
CN991
+V
-V
CN993
CN991
SVR
10000W Power Supply with Single Output
RST-10000 series
File Name:RST-10000-SPEC 2018-01-15
7.Current Sharing
RST-10000 has the built-in active current sharing function and can be connected in parallel, up to 2 units, to provide higher output power as exhibited below :
The voltage difference among each output should be minimized that less than 0.2V is required.
The total output current must not exceed the value determined by the following equation.
Maximum output current at parallel operation=(The rated current per unit)x(Number of unit)x0.9
Load
-V
+V
-S
+S
DIP
SW
CN993
CN992
CN991
DIP
SW
CN991
+V
+V
-V
-V
CN993
CN992
+S,-S and CS+, CS- and RC+, RC- are connected mutually in parallel.
When the remote sense function is used in parallel operation, the sensing wire must be connected only to the master unit.
Wires of the remote sense function should be kept at least 30 cm from input wires.
×When the total output current is less than 5% of the total rated current, or say (5% of Rated current per unit) (Number of unit)
the current shared among units may not be fully balanced.
Mechanical Specification
Case No.234A Unit:mm
10.2
483.6
466.1
19
102
Mounting Instruction
Hole No. Recommended Screw Size MAX. Penetration Depth L Recommended mounting torque
1
5mm
M4
Control Pin No. Assignment : HRS DF11-10DP-2DS or equivalent()CN992,CN993
CN992 and CN993 are connected internally.
Mating Housing
Terminal
HRS DF11-10DS or equivalent
HRS DF11-**SC or equivalent
7~1 Kgf-cm0
1
1
1
1
1
1
1 1
1 1
1 1
1 1
Pin No. Function
Description
1
3
4
7
8
2
6
9
10
CS-
+S
PV-
PC-
RC-
CS+
PV+
PC+
RC+
Current sharing signal. When units are connected in parallel, the CS pins of the units should be connected to allow current balance
between units.
Positive sensing for remote sense.
Connection for output voltage .programming
Connection for output current programming.
The output can be turned ON-OFF in association with RC+ and RC-.
10000W Power Supply with Single Output
RST-10000 series
File Name:RST-10000-SPEC 2018-01-15
83.5
424
21
488
540
4-M4 L=5mm
22.7
38
Air flow
direction
45.5
45.5
120
120
120
120
91.6
91.6
30
TB1
22.7
38
LED1
LED1
LED2
LED2
SVR
SVR
60
102.9406
8-M4 L=5mm
22max
1
2
3
4
5
6
+V
-V
Screw "A"
4-M4 L=5mm
21
488
540
10
13
123
DIP-SW
ON
CN993 CN992
CN991
+
+
86
4
3
5
7
10
9
6
4
2
1
3
5
CN992
CN993
2
1
8
7
10
9
86
4
2
1
3
5
7
10
9
12
11
14
13
16
15
18
17
20
19
CN991
7.1
7
7.4
68.75
Mounting Screw
Mounting Surface
Chassis of RST-10000
L
5-S
Negative sensing for remote sense.
2-M3
2 8.5

RST-10000-36

Mfr. #:
Manufacturer:
Description:
AC/DC Power Supply Single-OUT 36V 276A 9.936KW 36-Pin
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet