PS9124 Chapter Title
R08DS0049EJ0100 Rev.1.00 Page 14 of 15
Aug 30, 2013
SPECIFICATION OF VDE MARKS LICENSE DOCUMENT
Parameter Symbol Spec. Unit
Maximum repetitive peak operating isolation voltage U
IORM
707 V
peak
Partial discharge test voltage at 100% production test
U
pr
= 1.875 × U
IORM
, Method b, t
m
=1sec, p
d
< 5 pC
U
pr
1 326 V
peak
Partial discharge test voltage at Type test and Sample test
U
pr
= 1.6 × U
IORM
, Method a, t
m
=10sec, p
d
< 5 pC
U
pr
1 131 V
peak
Maximum transient isolation voltage (Transient overvoltage t
ini
=60sec) U
IOTM
6 000 V
peak
Installation classification (IEC 60664/ DIN EN 60664-1/ VDE0110 Part 1)
for rated mains voltage <
300 Vr.m.s.
for rated mains voltage <
600 Vr.m.s.
I - IV
I - III
Comparative tracking index (IEC 60112/ DIN EN 60112/ VDE 0303 Part 11) CTI 175
Material group (DIN EN 60664-1/ VDE0110 Part 1) III a
Pollution degree (DIN EN 60664-1/ VDE0110 Part 1) 2
Climatic category (IEC 60068-1/ DIN EN 60068-1) 40/110/21
Operating temperature range T
A
–40 to +110 °C
Storage temperature range T
stg
–55 to +125 °C
Isolation resistance, minimum value
V
IO
= 500 Vdc at T
A
=25°C
V
IO
= 500 Vdc at T
A
MAX. at least 100°C
Ris MIN.
Ris MIN.
10
12
10
11
Ω
Ω
Safety limiting values ratings (maximum allowable in the event of a fault
or a failure, see thermal derating curve)
Maximum ambient safety temperature
Maximum input current
Maximum output power
Isolation resistance at V
IO
= 500 Vdc, T
A
=Ts
Ts
Isi
Pso
Ris MIN.
150
200
300
10
9
°C
mA
mW
Ω
<R>