IAM-92516-TR2

4
IAM-92516 Typical Performance
DC =5V @ 26 mA, RF =1.91 GHz, Pin
RF
= -10 dBm; LO = 1.7 GHz, Pin
LO
= -3 dBm, IF = 210 MHz unless otherwise speci ed
Figure 4. Conversion Loss vs LO Power Over
Temperature.
CONVERSION LOSS (dB)
-5
-5.2
-5.4
-5.6
-5.8
-6
-6.2
-6.4
-6.6
-6.8
-7
-7.2
-7.4
-7.6
LO POWER (dBm)
-10 -6 -5
-9
-8 -7
-3 -2 -1
0 1 2 3 4-4 5
-20C
-40C
+25C
+85C
Figure 5. IIP3 vs LO Power Over Temperature.
IIP3 (dBm)
33
31
29
27
25
23
21
19
17
15
LO POWER (dBm)
-10 -6 -5
-9
-8 -7
-3 -2 -1
0 1 2 3 4-4 5
-20C
-40C
+25C
+85C
Figure 6. Ids vs LO Power Over Temperature.
Ids (mA)
30
29
28
27
26
25
24
23
22
LO POWER (dBm)
-10 -6 -5
-9
-8 -7
-3 -2 -1
0 1 2 3 4-4 5
-20C
-40C
+25C
+85C
Figure 7. P1dB vs LO Power Over Temperature.
P1dB (dBm)
11
10
9
8
7
6
5
4
LO POWER (dBm)
-10 -6 -5
-9
-8 -7
-3 -2 -1
0 1 2 3 4-4 5
-20C
-40C
+25C
+85C
Figure 9. LO-IF Isolation vs LO Power Over
Temperature.
ISOLATION LO-IF (dB)
-52
-54
-56
-58
-60
-62
-64
-66
LO POWER (dBm)
-10 -6 -5
-9
-8 -7
-3 -2 -1
0 1 2 3 4-4 5
-20C
-40C
+25C
+85C
Figure 8. SSB NF vs LO Power Over Temperature.
SSB NOISE FIGURE (dB)
31
29
27
25
23
21
19
17
15
13
11
9
7
5
LO POWER (dBm)
-10 -6 -5
-9
-8 -7
-3 -2 -1
0 1 2 3 4-4 5
-20C
-40C
+25C
+85C
Notes:
7. Typical performance plots are based on test board shown at Figure
1 with matching circuit stated at Figure 2.
8. Operating temperature range of Mini-circuit RF transformer (model:
TCM4-6T) is - 20°C to 85°C.
9. Conversion loss, P1dB and NF plots have de-embedded balun loss
0.8 dB @ 210 MHz.
5
IAM-92516 Typical Performance, continued
DC = 5V @ 26 mA, RF =1.91 GHz, Pin
RF
= -10 dBm; LO = 1.7 GHz, Pin
LO
= -3 dBm, IF = 210 MHz unless otherwise speci ed
Figure 11. RF-IF Isolation vs LO Power Over
Temperature.
ISOLATION RF-IF (dB)
-30
-31
-32
-33
-34
-35
-36
-37
-38
-39
-40
LO POWER (dBm)
-10 -6 -5
-9
-8 -7
-3 -2 -1
0 1 2 3 4-4 5
-20C
-40C
+25C
+85C
Figure 12. RF Return Loss vs Frequency.
RF RETURN LOSS (dB)
0
-2
-4
-6
-8
-10
-12
-14
-16
-18
-20
FREQUENCY (GHz)
0 1.5
0.5
1
2.5 3 3.5
4 4.5 5 5.52 6
Figure 13. LO Return Loss vs Frequency.
LO RETURN LOSS (dB)
0
-5
-10
-15
-20
-25
-30
FREQUENCY (GHz)
0 1.5
0.5
1
2.5 3 3.5
4 4.5 5 5.52 6
Figure 14. IF Return Loss vs Frequency.
IF RETURN LOSS (dB)
0
-2
-4
-6
-8
-10
-12
-14
-16
-18
-20
-22
-24
FREQUENCY (MHz)
50 150
100
250 300 350 400 450200 500
Figure 10. LO-RF Isolation vs LO Power Over
Temperature.
ISOLATION LO-RF (dB)
-22
-24
-26
-28
-30
-32
-34
-36
-38
-40
-42
-44
-46
LO POWER (dBm)
-10 -6 -5
-9
-8 -7
-3 -2 -1
0 1 2 3 4-4 5
-20C
-40C
+25C
+85C
LO Harmonics (nLO)
0 1 2 3 4 5
0 0 18.5 12.9 11.6 5.8
1 19.5 0 51.3 60.6 42.8 55.2
2 39.9 67.3 56.6 78.3 64.7 87.2
3 51.2 >90 >90 >90 >90 >90
4 68.9 >90 >90 >90 >90 >90
5 >90 >90 >90 >90 >90 >90
Harmonic Intermodulation Suppression
[10 ]
Note:
10. Test Conditions of Harmonic Intermodulation Suppression:
a) RF =1.91 GHz @-10 dBm and LO =1.7 GHz @-3 dBm.
b) RF harmonics and intermodulation products are referenced to a desired signal produced
by frequency IF = 210 MHz.
c) LO Harmonics are referenced to the -3 dBm LO drive signal.
RF Harmonics (mRF)
6
Ordering Information
Part Number Devices per Container Container
IAM-92516-TR1 1000 7" reel
IAM-92516-TR2 5000 13" reel
IAM-92516-BLK 100 antistatic bag
LPCC 3x3 Package Dimensions
PCB Layout and Stencil Design
Refer to Avagos web site
www.avagotech.com/view/rf
E2
DIMENSIONS ARE IN MILLIMETERS
1GL 3X3-0.50
MIN.
0.80
2.90
1.70
2.90
1.70
0
0.20
NOM.
0.90
3.00
1.80
3.00
1.80
0.50 BSC.
0.02
0.20 REF.
MAX.
1.00
3.10
1.90
3.10
1.90
0.05
REF.
A
D
D2
E
E2
e
A1
A3
k
Bottom View
Top View
Side View
PACKAGE
D2
A3
A1
A
E
2
D
2
D2
2
E2
2
E
D
k
e
INDEX AREA
(D/2 X E/2)
SEATING PLANE
e
2

IAM-92516-TR2

Mfr. #:
Manufacturer:
Broadcom / Avago
Description:
Up-Down Converters RFIC GaAs Mixer
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet