201-4A

Thermal-Magnetic Circuit Breaker 201
www.e-t-a.de
1623
1
1
Description
Typical applications
Ordering information
Approvals
Technical data
Single pole thermal-magnetic circuit breaker with tease-free, trip-free,
snap action mechanism and two button operation (M-type TM CBE
to EN 60934). Featuring a narrow profile housing, recessed terminals,
standard EN rail mounting, and precision CBE performance.
Approved to CBE standard EN 60934 (IEC 60934).
Process control systems, instrumentation, rail vehicles.
201-...
For further details please see chapter: Technical Information
Voltage rating AC 240 V (50/60 Hz); DC 65 V
(UL: AC 250 V; DC 80 V)
Current rating range 0.05...16 A
Typical life 5,000 operations at 1 x I
N
, inductive
5,000 operations at 2 x I
N
, resistive
Ambient temperature -30...+60 °C (-22...+140 °F)
Insulation co-ordination rated impulse pollution
(IEC 60664 and 60664 A) withstand voltage degree
2.5 kV 2
reinforced insulation in operating area
Dielectric strength
(IEC 60664 and 60664A) test voltage
operating area AC 3,000 V
Insulation resistance > 100 MΩ (DC 500 V)
Interrupting capacity I
cn
0.05...0.8 A self-limiting
1...2 A 200 A
2.5...16 A 400 A
Interrupting capacity I
N
U
N
(UL 1077) 0.05...16 A AC 250 V 1,000 A
0.05...16 A DC 80 V 1,000 A
Degree of protection operating area IP40
(IEC 60529/DIN 40050) terminal area IP20
Vibration 5 g (57-500 Hz), ± 0.38 mm (10-57 Hz)
to IEC 60068-2-6, test Fc
10 frequency cycles/axis
Shock 25 g (11 ms)
to IEC 60068-2-27, test Ea
Corrosion 96 hours at 5 % salt mist,
to IEC 60068-2-11, test Ka
Humidity 240 hours at 95 % RH
to IEC 60068-2-78, test Cab
Mass approx. 60 g
Standard current ratings and typical internal resistance values
Type No.
201 single pole, rail mounted version
Current ratings
0.05...16 A
201 - 10 A ordering example
The exact part number required can be built up from the table of choices shown
above. Ordering references for optional features should be omitted if not required.
Current rating
(A)
Internal
resistance (Ω)
Current rating
(A)
Internal
resistance (Ω)
0.05 447
3 0.19
0.1 131
4 0.090
0.2 40
5 0.061
0.3 19.3 6 0.041
0.4 10.4 7 0.034
0.5 7.1 8 < 0.02
0.6 4.3
10 < 0.02
0.8 2.5 12 < 0.02
1 1.67
14 < 0.02
1.5 0.61
15 < 0.02
2 0.38 16 < 0.02
2.5 0.24
Preferred types Standard current ratings (A)
0.5 1 2 3 4 5 8 10 15 16
201-
x x x x x x x x x x
Preferred types
Authority Standard Rated voltage Current ratings
VDE IEC/EN 60934 AC 240 V
DC 65 V
0.05 A…16 A
0.05 A…16 A
UL UL 1077
C22.2 No 235
AC 250 V
DC 80 V
0.05 A…16 A
0.05 A…16 A
CSA C22.2 No 235 AC 250 V
DC 80 V
0.05 A…16 A
0.05 A…16 A
Thermal-Magnetic Circuit Breaker 201
www.e-t-a.de
1623
2
1
Ambient temp. °F
°C
-22
-30
-4
-20
+14
-10
+32
0
+73.4
+23
+104
+40
+122
+50
+140
+60
The time/current characteristic curve depends on the ambient temperature
prevailing. In order to eliminate nuisance tripping, please multiply the circuit
breaker current ratings by the derating factor shown below. See also section
Technical information.
Derating factor
0.76 0.79 0.83 0.88 1 1.08 1.16 1.24
Dimensions
6.5
4.8
7.5
ø8.5
symmetrical rail EN 50022-35x7.5
current rating in A
45
11
5
53
80
43
2
Phillips screw, size 2 to EN ISO 4757
OFF
ON
slot for fitting labels from
conductor cross
section max.
0.5 - 10 mm
2
(AWG 20-AWG 8)
rigid conductor
0.5 - 6 mm
2
(AWG 20-AWG 10)
flexible conductor
tightening torque
max. 0.8 Nm
11.5
12.5
.335
1.77
.197
.433
2.09
12-14
.472-.551
.189
.295
3.15
1.69
.492
.256
.453
white
black
Weidmüller
type dekafix
Phoenix
type ZBFM5 or ZB8
line 1
2
I
>
Installation drawing
mounting area
operating area
(reinforced insulation)
cable entry
cable entry
Typical time/current characteristics
Internal connection diagram
+23 °C
+73.4 °F
… times rated current
+60 °C
+140 °F
-30 °C
-22 °F
12468
10 20 40
… times rated current
10000
1000
100
10
1
0.1
0.01
0.001
60 80100
Trip time in seconds
12468
10 20 40
10000
1000
100
10
1
0.1
0.01
0.001
60 80100
Trip time in seconds
1)
Magnetic tripping currents are increased by 20% on DC supplies.
0.05...7 A AC/DC
1)
8...16 A AC/DC
1)
This is a metric design and millimeter dimensions take precedence (
mm
)
inch
Thermal-Magnetic Circuit Breaker 201
www.e-t-a.de
1623
3
1
Thermal-Magnetic Circuit Breaker 201
Accessories
79 x 12.5 = 987.5
12.5
3
±0.2
1.5
20-1
16-1
14.7
4.6
995
+2
Art.-Nr. X22254001
EC 664 500 V/100 A (40 °C)
Art.-Nr. X22254001
EC 664 500 V/100 A (40 °C)
marking 4 x on busbar
Supply terminal I
max
63 A
Y 308 551 01
Max. tightening torque of terminal screw 2 Nm
Max. cable cross section:
25 mm
2
/ single strand
16 mm
2
/ multistrand
with wire end ferrule
4
20
37.5
13
2
17.7
Busbar 1-pole, 90°
X 222 540 01
The one metre long busbars can be cut to suitable lengths.
Plug-on caps can be fitted on the ends to provide brush
contact protection.
I
max
- busbar 100 A (40 °C)
.118
±.008
.492
79 x .492 = 38.878
.579
.181
.059
.630-.039
.787-.039
39.173
+.079
.157
.079
1.476
.787
.512
.697
Elektrotechnische Apparate GmbH
D-90418 Altdorf bei Nürnberg
Elektrotechnische Apparate GmbH
D-90418 Altdorf bei Nürnberg
Plug-on cap, 1-pole
Y 307 851 01
This is a metric design and millimeter dimensions take precedence (
mm
)
inch
All dimensions without tolerances are for reference only. In the interest of improved design,
performance and cost effectiveness the right to make changes in these specifications
without notice is reserved.Product markings may not be exactly as the ordering codes.
Errors and omissions excepted.
Connector bus links -K10
X
210 589 01/2.5 mm
2
, (AWG 14) (black) up to 20 A max. load
X
210 589 02/1.5 mm
2
, (AWG 16) (brown) up to 13 A max. load
50 pin lugs to DIN 46230
tinned copper
ø2.5
.099
~70
~2.76

201-4A

Mfr. #:
Manufacturer:
E-T-A Circuit Breakers
Description:
Circuit Breakers 1077, 1P, DN, 120-240VAC/80VDC, 4A
Lifecycle: