GP1UM270XK0F

GP1UM26XK/27XK/28XK/28YK Series
Fig.1 Transmitter
20cm
10k
+5V
10µF
PD49PI
10k
V
OUT
Oscilloscope
Transmitter (GL521 used)
f
0
=(*4)
Duty 50%
In the above figure, the transmitter should be set so that the output V
OUT (P-P)
can be 40mV.
However, the PD49PI to be used here should be of the short-circuit current I
SC
=2.6µA at E
V
=100 lx.
(E
V
is an illuminance by CIE standard light source A (tungsten lamp).)
Performance
Using the transmitter shown in Fig. 1, the output signal of the light detecting unit is good enough to meet the following items in the
standard optical system in Fig. 2.
1. Linear reception distance characteristics
When L=0.2 to 10.5(9.0)
*7
m,
*5
E
V
<10 lx and φ=0˚ in Fig.2, the output signal shall meet the electrical characteristics in the attached list.
2. Sensitivity angle reception distance characteristics
When L=0.2 to 7.5(6.5)
*7
m,
*5
E
V
<10 lx and φ≤30˚ in Fig.2, the output signal shall meet the electrical characteristics in the attached list.
3. Anti outer peripheral light reception distance characteristics
When L=0.2 to 5.0(4.0)
*7
m,
*6
E
V
300 lx and φ=0˚ in Fig.2, the output signal shall meet the electrical characteristics in the attached list.
*5 It refers to detector face illuminance
*6 Outer peripheral light source: CIE standard light source A shall be used and placed at 45˚ from perpendicular axis at the detector face center
*7 In case of B.P.F. center frequency: 56.8kHz model
Fig.2 Standard Optical System
φ
φ
Transmitter
Reception distance:L
Light detector face illuminance:E
V
(φ indicates horizontal and vertical directions.)
V
OUT
GP1UM26XK/27XK/28XK/28YK Series
1. When this infrared remote control detecting unit shall be adopted for wireless remote control, please use it with the signal format of
transmitter, which total duty ratio D
t
(Emitting time
n
Σ t
N
/ Transmitting time for 1 block T) is 40% or less. ON signal time T
ON
(Pulse width of the presence of modulated IR) should be 250(200:In case of B.P.F center frequency:56.8kHz model)µs or more. In
case that the signal format of total duty and ON signal time is out of above conditions, there is a case that reception distance is
much reduced or output is not appeared.
2. Use the light emitting unit (remote control transmitter), in consideration of performance, characteristics, operating conditions of
light emitting device and the characteristics of the light detecting unit.
3. Pay attention to a malfunction of the light detecting unit when the surface is stained with dust and refuse.
Care must be taken not to touch the light detector surface.
If it should be dirty, wipe off such dust and refuse with soft cloth so as to prevent scratch. In case some solvents are required, use
methyl alcohol, ethyl alcohol or isopropyl alcohol only.
Also, protect the light detecting unit against flux and others, since their deposition on the unit inside causes reduction of the
function, fading of markings such as the part number.
4. The shield case should be grounded on PCB pattern.
(The area across the shield case and the GND terminal is internally conductive in some cases and non-conductive in some other
cases.)
5. Do not apply unnecessary force to the terminal and the case.
6. Do not push the light detector surface (photodiode) from outside.
7. To avoid the electrostatic breakdown of IC, handle the unit under the condition of grounding with human body, soldering iron, etc.
8. Do not use hole and groove set in the case of the light detecting unit for other purposes, since they are required to maintain the
specified performance.
9. External Circuit Examples (Mount the outer parts as near the unit as possible).
Precautions for Operation
N=1
t
1
t
2
t
3
t
n
T
ON
Transmitting time for 1 block:T
D
t
=( Σ t
N
/ T)×100 (%)
n
N=1
GND
(Circuit parameters)
R
1
=47Ω±5%
C
1
=47µF
C
O
+
V
e
V
O
GND
V
CC
V
OUT
R
1
In setting R
1
and C
1
, use suitable values after considering under the real condition
The circuit constant is a example. It is difference from mounting equipment. Please select it by your mounting equipment.
This device has a transistor as protection element between V
CC
and GND to improve anti-static electricity proof.
Please be carefully not to apply exceeding the absolute maximum ratings of applying voltage and continuous high voltage spike
noise because there is cases that transistor will be short by secondary breakdown generally. In order to do difficultly, Please add
CR filter(47(1/10W), 10µF or more)such as external circuit example above near V
CC
.
GP1UM26XK/27XK/28XK/28YK Series
10. There is a possibility that noise on output may be caused by environmental condition (Disturbing light noise, Electromagnetic
noise, Power supply line noise, etc.) even if there is no input transmission signal.
11. Please shall confirm operation or your actual machine. Because the output pulse width of this product is fluctuated by
environmental conditions such as signal format, temperature, distance from transmitter, and so on.
12. In case that this product is kept in high humidity condition, it may be hard to solder, please be careful enough about storage
method.
Depend on the flux you select, there are different solderabilities, so please select a suitable flux and use it.
13. Please use this device away from the dew drop.
Be aware that the dew drop rusts shield case and others, may affect the electric characteristics.

GP1UM270XK0F

Mfr. #:
Manufacturer:
Sharp Microelectronics
Description:
Infrared Receivers Rem Cont Rec 5V 36 kHz
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment: