241-800-526-2324 • www.us.tdk-lambda.com/lp/ Disclaimer: us.tdk-lambda.com/lp/legal.htm
CPFE500F Series
Features
Base plate cooled, no fan required
High ef ciency
Protective coating option
MIL STD 461/462D CE102 Conducted EMC
500W Conduction Cooled Power Supplies
(1) 100/200VAC
(2) CPFE500F-12: -40 to 80°C. See instruction manuals for derating curves
(3) Reduced PFC above 63Hz. Contact technical support for 440Hz operation.
Model
AC Input VAC/Hz 90 to 265VAC, 47-63Hz (up to 440Hz) (3)
Input Current Model dependant (1) A 6.8 / 3.4
Inrush Current (115 / 230VAC) A 20 / 40 peak
Power Factor - Meets EN61000-3-2
Ef ciency (typical) % 85% at 75% loading (Non ORing diode versions)
Output Voltage Setpoint Accuracy - ±2% at 50% load
Total Regulation % < 4%. (ORing diode option, adds 1V to load regulation)
Ripple and Noise (20MHz BW) - 1% (1.5% below -10°C)
Over Current Protection % 105 - 140% (Automatic Recovery)
Over Voltage Protection - 125 - 145% (Cycle AC to reset)
Series Operation - Yes
Parallel Operation - Yes (Single wire, up to 6 units)
ORing Diodes/FETs - Yes (option)
Power On Signal (ENA) - Open collector (10mA sink current). Low (on) when output is present
Auxiliary Supply - 10 - 14V, 20mA
Remote On/Off (Opto isolated) - High = On
Temperature Coef cient - <0.01%/°C
Overtemperature °C Shuts down between 90 - 130°C (Cycle AC to reset)
Hold Up Time (230VAC) ms 10ms
Leakage Curr. (at 230VAC, 50Hz) mA < 1.5mA
Remote Sense - Yes, compensates up to 500mV cable drop
Operating Temp. (Base plate) °C -40 to +85°C (2)
Storage Temperature °C -40 to +100°C
Humidity - Operating: 20 - 95%RH, Non operating 10 - 95%RH (Pcb assembly protective coated)
Cooling - Conduction cooled through 6mm base plate
Withstand Voltage - Input to Output 4242VDC, Input to Ground 2121VDC, Output to ground 500VDC
Vibration (non operating) - MIL-STD-810E, Method 514.4, Proc 1, Category 1, 9
Shock - MIL-STD-810E, Method 516.5, Proc. I, IV, VI
Safety Agency Approvals - UL60950-1, CSA 22.2 No 60950-1, EN60950-1 (Ed 2), CE Mark
Line Dip - Complies with SEMI F47 (200VAC line only)
Conducted EMI - EN55011, EN55022 (as per CISPR, 11/22) Class B, FCC47 part 15 subpart B)
MIL STD 461E/461E/462D CE102, 115V and 220V
Radiated EMI - EN55011, EN55022 (as per CISPR, 11/22) Class B, FCC47 part 15 subpart B) see app. note for details
Immunity - IEC61000-4-2 (Contact Level 2, Air discharge Lvl 3), -3 (Lvl 3), -4(Lvl 3), -5 (Lvl 4),
-6 (Lvl 3), -8 (Lvl 4), -11 (Class 3 ), -12 (Lvl 3), -14 (Class 3)
Weight (Typ) g with cover 1400g, without cover 1200g
Size (L x W x D) mm 270 x 126 x 55mm
Warranty yrs 2 years
Speci cations
Key Market Segments & Applications
251-800-526-2324 • www.us.tdk-lambda.com/lp/
Revision A8: Sept 2013
CPFE500F Series
Outline Drawing
For Additional Information, please visit
us.tdk-lambda.com/lp/products/cpfe-series.htm



Notes 1. All customer fixings 10 x M4 clearance holes
2. All tolerances +/-0.5m m
CPFE500F
Pin Function
10 Do not connect
9 Output good - ENA
8 Tr im
7 Current share
6 Aux
5 +remote on/off
4 -remote on/off
3 Aux commo n
2 - Sense
1 + Sense
ac input connector
Housing Tyco 350766-4
Crimp 926895-1 (3 of f)
or equivalent
Live
Earth
Neutral
Signals Connections
Housing - Molex 22-01-1 102
Crimp - Molex 50802 series
(or equivalents)
dc output
M6 x 18 stud for +ve output
M6 x 18 stud for -ve output
M6 nut, spring washer and
flat washer supplied for each
terminal
1
10
Output Adjust Max Max
Model Volt (V) Range (V) Curr (A) Watt (W)
CPFE500F-12-NLC 12 9.6 - 14.4 42 504
CPFE500F-24-NLC 24 22.4 - 33.6 18 504
CPFE500F-28-NLC 28 22.4 - 33.6 18 504
CPFE500F-48-NLC 48 38.4 - 57.6 10.5 504
ORing Protective
Part Number Desc. Suf x Diode (3) Cover Coating
-DLC Y Y Y
-NLC N Y Y
3) Reduces maximum output adjustment range by 1V
Preferred stocking part highlighted in green.
Model Selector Options

CPFE500F-48-NLC

Mfr. #:
Manufacturer:
TDK-Lambda
Description:
Switching Power Supplies 504W 48V 10.5A Protective coating
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union