SPECIFICATION
36WAC-DC High Reliability MedicalAdaptor
GSM36E series
File Name:GSM36E-SPEC 2018-01-15
ORDER NO.
SAFETY MODEL NO.
DC VOLTAGE
Note.2
RATED CURRENT
CURRENT RANGE
RATED POWER (max.)
RIPPLE & NOISE (max.)
Note.3
OUTPUT
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INPUT
ENVIRONMENT
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT(max.)
SAFETY STANDARDS
SAFETY &
EMC
(Note. 8)
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSION
OTHERS
NOTE
PACKING
PROTECTION
5V
GSM36E05
GSM36E05-P1J
GSM36E07-P1J
GSM36E09-P1J
GSM36E12-P1J
GSM36E15-P1J
GSM36E18-P1J
GSM36E24-P1J
GSM36E48-P1J
7.5V
GSM36E07
9V
GSM36E09
12V
GSM36E12
15V
GSM36E15
18V
GSM36E18
24V
GSM36E24
48V
GSM36E48
80mVp-p 80mVp-p 80mVp-p 120mVp-p 120mVp-p 150mVp-p 180mVp-p 240mVp-p
VOLTAGE TOLERANCE
Note.4
LINE REGULATION Note.5
LOAD REGULATION
80 ~ 264VAC 113 ~ 370VDC
47 ~ 63Hz
15.75 ~ 20.25V 25.2 ~ 32.4V 50.4 ~ 64.8V
0.9A / 115VAC 0.45A / 230VAC
55A / 230VAC 30A / 115VAC
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
657.4K hrs min. MIL-HDBK-217F(25 )℃
-25 ~ +60 (Refer to "Derating Curve")℃
20% ~ 90% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH℃
±℃℃0.03% / (0~40 )
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
79*54*33mm (L*W*H)
230g ; 60pcs / 14.8Kg / CARTON
CONNECTOR
PLUG
CABLE
1. All parameters are specified at 230VAC input, rated load, 25 70% RH ambient. ℃
2. DC voltage: The output voltage set at point measure by plug terminal & 50% load.
3. Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
4. Tolerance: includes set up tolerance, line regulation, load regulation.
5. Line regulation is measured from low line to high line at rated load.
6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
7. Derating may be needed under low input voltage. Please check the derating curve for more details.
8. The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the
EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on http://www.meanwell.com)
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN60601-1-2, EN61204-3 medical level, criteria A, EAC TP TC 020
OVERLOAD
OVER VOLTAGE
105 ~ 170% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
5.25 ~ 7.5V
Protection type : Shut down o/p voltage, re-power on to recover
500ms, 30ms / 230VAC 1000ms, 30ms / 115VAC at full load
16ms / 230VAC 16ms / 115VAC at full load
SETUP, RISE TIME
Note.6
HOLD UP TIME (Typ.)
I/P-O/P:4KVAC
I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH℃
EMC IMMUNITY
EMC EMISSION
TUV EN60601-1 / 60601-1-11, approved
EAC TP TC 004
±6.0% ±5.0% ±5.0% ±3.0% ±3.0% ±3.0% ±2.0% ±2.0%
±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0%
±6.0% ±5.0% ±5.0% ±3.0% ±3.0% ±3.0% ±2.0% ±2.0%
80% 83% 84% 86% 87% 87% 87% 88%
4.5A 4.32A 4A 3A 2.4A 2A 1.5A 0.75A
0 ~ 4.5A 0 ~ 4.32A 0 ~ 4A 0 ~ 2.4A 0 ~ 2A 0 ~ 1.5A
0 ~ 0.75A
22.5W 32.4W 36W 36W
0 ~ 3A
36W 36W 36W 36W
Compliance to EN55011(CISPR11) class B, EN61000-3-2,3, EAC TP TC 020
Touch current < 50 A/264VAC
μ
7.88 ~ 10.5V 9.45 ~ 13V 12.6 ~ 17.2V 18.9 ~ 25.2V
VOLTAGE RANGE
Note.7
See page 3 ; Other type available by customer requested
See page 3 ; Other type available by customer requested