RECOMMENDED OPERATING CONDITIONS
PARAMETER TEST CONDITION SYMBOL MIN. MAX. UNIT
Forward current at on-state
Input
I
F(ON)
10 20 mA
Forward current at off-state I
F(OFF)
00.1mA
Load supply voltage
Output
With snubber
(0.022 μF, 47 Ω)
V
OUT(RMS)
240 V
On-state RMS current
T
A
= 40 °C
On 4-layer PCB
(R
BA
= 30 °C/W)
I
OUT(RMS)
0.8 A
T
A
= 60 °C 0.6 A
Frequency f5060Hz
Operating temperature - 40 85 °C
SAFETY AND INSULATION RATINGS
PARAMETER TEST CONDITION SYMBOL MIN. TYP. MAX. UNIT
Climatic classification IEC 68 part 1 40/85/21
Pollution degree DIN VDE 0109 2
Tracking resistance (comparative tracking index) Insulation group IIIa CTI 175
Highest allowable overvoltage
Transient
overvoltage
V
IOTM
8000 V
peak
Maximum working insulation voltage
Recurring peak
voltage
V
IORM
890 V
peak
Insulation resistance at 25 °C V
IO
= 500 V R
IS
≥ 10
12
Ω
Insulation resistance at T
S
V
IO
= 500 V R
IS
≥ 10
9
Ω
Insulation resistance at 100 °C V
IO
= 500 V R
IS
≥ 10
11
Ω
Partial discharge test voltage
Method b,
V
pd
= V
IORM
x 1.6
V
pd
1424 V
peak
Safety limiting values -
maximum values allowed in the
event of a failure
Output power P
SO
2W
Input current I
SI
150 mA
Case temperature T
SI
165 °C
Minimum external air gap (clearance)
Measured from input
terminals to output
terminals, shortest
distance through air
≥ 7mm
Minimum external tracking (creepage)
Measured from input
terminals to output
terminals, shortest
distance path along
body
≥ 7mm