82A6013-6

Users should evaluate the suitability of this product for their application. Specications are subject to change without notice.
Tyco Electronics also reserves the right to make changes in materials or processing, which do not affect compliance with any specication, without notication to Buyer.
1/ COLORS SHALL BE IN ACCORDANCE WITH MIL-STD-681. OTHER CODES AND SUFFIXES MAY BE ADDED TO THE PART
NUMBER. AS NECESSARY, TO CAPTURE ANY ADDITIONAL REQUIREMENTS IMPOSED BY THE PURCHASE ORDER.
Page 1 of 2
The TE logo, Tyco Electronics and Raychem are trademarks.
NOMEX is a registered trademark of E.I. du Pont de Nemours and Company
Raychem Wire & Cable
501 Oakside Avenue
Redwood City, CA 94063-3800
Phone: 1-800-227-8816
Fax: 1-650-361-6297
DIMENSIONS ARE IN INCHES, AND UNLESS OTHERWISE DESIGNATED ARE NOMINAL.
THIS SPECIFICATION SHEET TAKES PRECEDENCE OVER DOCUMENTS REFERENCED HEREIN.
REFERENCED DOCUMENTS SHALL BE OF THE ISSUE IN EFFECT ON DATE OF INVITATION FOR BID.
© 2010 Tyco Electronics Corporation. All rights reserved.
TABLE I. CONSTRUCTION DETAILS
PART NUMBER
1/
WIRE
SIZE
(AWG)
CONDUCTOR
STRANDING
(number x AWG)
DIAMETER OF
STRANDED
CONDUCTOR
(in.)
FINISHED WIRE
MAXIMUM
RESISTANCE
AT 20°C
(ohms/1000 ft.)
DIAMETER
(in.)
MAXIMUM
WEIGHT
(lbs/1000 ft.)
MINIMUM MAXIMUM
82A6013-8 8 665 x 36 .157 .173 .714 .245 ± .008 81.2
82A6013-6 6 1045 x 36 .192 .208 .490 .292 ± .010 123.
82A6013-4 4 1665 x 36 .265 .285 .326 .374 ± .010 196.
82A6013-2 2 1665 x 34 .325 .345 .204 .447 ± .016 291.
CONDUCTOR - NICKEL-COATED COPPER
JACKET - RADIATION-CROSSLINKED,
MODIFIED FLEXIBLE ETFE
COLOR - WHITE
SPECIFICATION CONTROL DRAWING
82A6013
WIRE, RADIATION-CROSSLINKED, MODIFIED FLEXIBLE ETFE-INSULATED,
NORMAL WEIGHT, GENERAL PURPOSE, 600 VOLT
8-4-10 D
This specication sheet forms a part of the latest issue of Raychem Specication 80.
TITLE
Date Revision
PRIMARY INSULATION - RADIATION-CROSSLINKED,
MODIFIED FLEXIBLE ETFE
COLOR - LIGHT GREEN
BRAID - NOMEX BRAID TREATED
TO PREVENT FRAYING
COLOR - WHITE
TABLE II. PERFORMANCE DETAILS
PART NUMBER
1/
BEND TESTING
MANDREL DIAMETER
(inch) (± 3%)
WEIGHT
(lb) (± 3%)
CROSSLINKING PROOF TEST CROSSLINKING PROOF TEST
82A6013-8 3.00 4.00
82A6013-6 4.00 4.00
82A6013-4 5.00 4.00
82A6013-2 6.00 6.00
SPECIFICATION CONTROL DRAWING
Page 2 of 2 D
82A6013
Revision SCD Number
WIRE RATINGS AND ADDITIONAL REQUIREMENTS
TEMPERATURE RATING: 200°C
Maximum continuous conductor temperature
VOLTAGE RATING: 600 volts (rms) at sea level
CONCENTRICITY: 70% (minimum)
CROSSLINKING PROOF TEST: 300 ± 3°C for 7 hours
INSULATION ELONGATION AND TENSILE STRENGTH:
Elongation, 125% (minimum)
Tensile Strength, 3000 lbf/in² (minimum)
INSULATION FLAWS:
Primary Insulation,
Spark Test, 1.5 kV (rms) at 3 kHz
Impulse Dielectric Test, 6.0 kV (peak)
Finished Wire,
Spark Test, 3.0 kV (rms) at 3 kHz
Impulse Dielectric Test, 8.0 kV (peak)
INSULATION THICKNESS:
AWG 8-4: .008 in. (minimum) for primary insulation
.012 in. (minimum) for outer jacket
AWG 2: .010 in. (minimum) for primary insulation
.015 in. (minimum) for outer jacket
SECANT MODULUS: (Test per ASTM D 882)
4.0 x 10
4
lbf/in
2
(maximum), 2% strain, 2 inch jaw separation, 0.2 inch/minute
SHRINKAGE: 200 ± 3°C for 6 hours, 0.25 in. (maximum) in 12 inches
VOLTAGE WITHSTAND (Post Environmental): 2500 volts (rms), 60 Hz
PRODUCT IDENTIFICATION: Braid shall be marked in a contrasting color at
12 inch (nominal) intervals as follows: “ 82A6013-AWG 06090 “
1/ See footer section on page 1

82A6013-6

Mfr. #:
Manufacturer:
Raychem / TE Connectivity
Description:
Multi-Conductor Cables 82A6013-6
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet