8
G6A G6A
G6AU-434P-ST-US, G6AU-474P-ST-US
Terminal arrangement/ Mounting holes
Internal connections (Bottom view)
(Bottom view)
G6AK-434P-ST(40)-US, G6AK-474P-ST(40)-US
Terminal arrangement/ Mounting holes
Internal connections (Bottom view)
(Bottom view)
Note: and indicate mounting orientation marks.
Type Contact form Coil rating Contact ratings
G6A-234P-ST-US DPDT 1 to 48 VDC 0.60 A, 125 VAC
G6A-234P-ST40-US 1 A, 30 VDC
G6A-234P-ST15-US 0.60 A, 110 V+DC
G6A-274P-ST-US 0.60 A, 125 VAC
G6A-274P-ST40-US 2 A, 30 VDC
G6A-274P-ST15-US 0.60 A, 110 VDC
G6A-434P-ST-US 4PDT 1 to 48 VDC 0.60 A, 125 VAC
G6A-434P-ST20-US 1 A, 30 VDC
G6A-434P-ST40-US 0.60 A, 110 VDC
G6A-474P-ST-US 0.60 A, 125 VAC
G6A-474P-ST20-US 2 A, 30 VDC
G6A-474P-ST40-US 0.60 A, 110 VDC
G6AK-234P-ST(40)-US DPDT 1 to 48 VDC 0.60 A, 125 VAC
G6AU-234P-ST-US 1 A, 30 VDC
0.60 A, 110 VDC
G6AK-274P-ST(40)-US 0.60 A, 125 VAC
G6AU-274P-ST-US 2 A, 30 VDC
0.60 A, 110 VDC
G6AK-434P-ST(40)-US 4PDT 1 to 48 VDC 0.60 A, 125 VAC
G6AU-434P-ST(40)-US 1 A, 30 VDC
0.60 A, 110 VDC
G6AK-474P-ST(40)-US 0.60 A, 125 VAC
G6AU-474P-ST(40)-US 2 A, 30 VDC
0.60 A, 110 VDC
■ APPROVALS
UL (File No. E41515)/CSA (File No. LR24825)
Note: 1. The rated values approved by each of the safety standards (e.g., UL and CSA) may be different from the performance
characteristics individually defined in this catalog.
2. In the interest of product improvement, specifications are subject to change.