FEDR44V064A-02
MR44V064A
12/16
•POWER-ON AND POWER-OFF CHARACTERISTICS
(Under recommended operating conditions)
Parameter Symbol Min. Max. Unit Note
Power-On SCL,SDA High Hold Time
t
VHEL
50 ⎯ μs 1, 2
Power-Off SCL, SDA High Hold Time
t
EHVL
100 ⎯ ns 1
Power-On Interval Time
t
VLVH
1 ⎯ μs 2
Notes:
1. To prevent an erroneous operation, be sure to maintain SCL=SDA="H", and set the FeRAM in an inactive
state (standby mode) before and after power-on and power-off.
2. Powering on at the intermediate voltage level will cause an erroneous operation; thus, be sure to power up
from 0 V.
3. Enter all signals at the same time as power-on or enter all signals after power-on.
•Power-On and Power-Off Sequences
•
After Power-Off, terminal state
When MR44V064A only goes power-off while the other IC’s on I2C bus are active, all the input pins including
I/O pin of MR44V064A must be GND level.
0
V
IL
Max.
V
CC
Min.
V
CC
V
IH
Min.
SCL,SD
0V
V
IL
Max.
V
CC
Min.
V
CC
V
IH
Min.
SCL,SDA
t
VHEL
t
VLVH
t
EHVL