9
Electrical Speci cations (DC)
For operating T
A
= +25°C
Parameter Sym. Min. Typ. Max. Units Conditions Fig. Note
Output Withstand
Voltage
|V
O(OFF)
| 400 450 V
V
F
=0.8V, I
O
=250 A
5
Output Leakage
Current
I
O(OFF)
0.005 1
A
V
F
=0.8V, V
O
=400V
Input Reverse
Breakdown Voltage
V
R
5V
I
R
=10 A
Input Forward
Voltage
V
F
1.1 1.3 1.6 V I
F
=5mA 6, 7
Output
On-resistance
R
(ON)
25 35
I
F
=5mA, I
O
=100mA,
Pulse
30ms
8, 9 6
ASSR-4119
Connection B
810
I
F
=5mA, I
O
=200mA,
Pulse
30ms
Switching Speci cations (AC)
For operating T
A
= +25°C
Parameter Sym. Min. Typ. Max. Units Conditions Fig. Note
Turn On Time T
ON
0.7 5.0 ms I
F
=5mA, I
O
=100mA
Turn O Time T
OFF
0.04 5.0 ms I
F
=5mA, I
O
=100mA
Notes:
1. For derating, refer to Figure 1, 2, 3 and 4.
2. The voltage across the output terminals of the relay should not exceed this rated withstand voltage. Over-voltage protection circuits should
be added in some applications to protect against over-voltage transients.
3. Threshold to switch device is I
F
0.5mA, however, for quali ed device performance over temperature range, it is recommended to operate at
I
F
=5mA.
4. Device is considered as a two terminal device:
ASSR-4118 - pin 1, 2 shorted and pin 3, 4 shorted.
ASSR-4119 - pin 1, 2, 3 shorted and pin 4, 5, 6 shorted.
ASSR-4128 - pin 1, 2, 3, 4 shorted and pin 5, 6, 7, 8 shorted.
5. The Input-Output Momentary Withstand Voltage is a dielectric voltage rating that should not be interpreted as an input-output continuous
voltage rating. For the continuous voltage rating refer to the IEC/EN/DIN EN 60747-5-2 Insulation Characteristics Table (if applicable), your
equipment level safety speci cation, or Avago Technologies Application Note 1074, “Optocoupler Input-Output Endurance Voltage.”
6. During the pulsed R
(ON)
measurement ( I
O
duration 30ms), ambient (T
A
) and case temperature (T
C
) are equal.