MPX2202
Sensors
Freescale Semiconductor, Inc. 3
Pressure
Operating Characteristics
Table 1. Operating Characteristics
(V
S
= 10 Vdc, T
A
= 25C unless otherwise noted, P1 > P2)
Characteristics Symbol Min Typ Max Unit
Pressure Range
(1)
Absolute Pressure Range MPX2202A
Differential Pressure Range MPX2202D
1. 1.0 kPa (kiloPascal) equals 0.145 psi.
P
OP
P
OP
20
0
—
—
200
200
kPa
kPa
Supply Voltage
(2)
2. Device is ratiometric within this specified excitation range. Operating the device above the specified excitation range may induce additional
error due to device self-heating.
V
S
—1016Vdc
Supply Current I
o
—6.0—mAdc
Full Scale Span
(3)
3. Full Scale Span (V
FSS
) is defined as the algebraic difference between the output voltage at full rated pressure and the output voltage at the
minimum rated pressure.
V
FSS
38.5 40 41.5 mV
Offset
(4)
MPX2202D, MPXM2202D/G Series
MPX2202A, MPXM2202A Series
4. Offset (V
off
) is defined as the output voltage at the minimum rated pressure.
V
off
-1.0
-2.0
—
—
1.0
2.0
mV
Sensitivity V/P— 0.2 —mV/kPa
Linearity
(5)
MPXM2202D/G, MPX2202D Series
MPXM2202A, MPX2202A Series
5. Accuracy (error budget) consists of the following:
Linearity:Output deviation from a straight line relationship with pressure, using end point method, over the specified pressure range.
Temperature Hysteresis:Output deviation at any temperature within the operating temperature range, after the temperature is cycled to and
from the minimum or maximum operating temperature points, with zero differential pressure applied.
Pressure Hysteresis:Output deviation at any pressure within the specified range, when this pressure is cycled to and from the minimum or
maximum rated pressure, at 25C.
TcSpan:Output deviation at full rated pressure over the temperature range of 0 to 85C, relative to 25C.
TcOffset:Output deviation with minimum rated pressure applied, over the temperature range of 0 to 85C, relative to 25C.
—-0.6
-1.0
—
—
0.4
1.0
%V
FSS
Pressure Hysteresis
(5)
(0 to 200 kPa)
—— 0.1 — %V
FSS
Temperature Hysteresis
(5)
(-40C to +125C)
—— 0.5 — %V
FSS
Temperature Effect on Full Scale Span
(5)
TCV
FSS
-2.0 — 2.0 %V
FSS
Temperature Effect on Offset
(5)
TCV
off
-1.0 — 1.0 mV
Input Impedance Z
in
1000 — 2500
Output Impedance Z
out
1400 — 3000
Response Time
(6)
(10% to 90%)
6. Response Time is defined as the time for the incremental change in the output to go from 10% to 90% of its final value when subjected to a
specified step change in pressure.
t
R
—1.0—ms
Warm-Up — — 20 — ms
Offset Stability
(7)
7. Offset stability is the product's output deviation when subjected to 1000 hours of Pulsed Pressure, Temperature Cycling with Bias Test.
——0.5 — %V
FSS