OV-24DC …
103082_01_en PHOENIX CONTACT 2
Ordering Data
Technical Data
Solid-State Relays With DC Voltage Output
Description Type Order No. Pcs./Pck.
Solid-state relay, for signal amplification and electrical isolation of the control
and load circuits, can be plugged into the SIM-AMS plug-in base, which can
be soldered, or mounted directly on the PCB with PCB connection,
input/output: DC voltage (350 V DC, maximum)
OV-24DC/350DC/1 2982634 10
Solid-state relay, for signal amplification and electrical isolation of the control
and load circuits, can be plugged into the SIM-AMS plug-in base, which can
be soldered, or mounted directly on the PCB with PCB connection,
input/output: DC voltage (60 V DC, maximum)
OV-24DC/ 60DC/4 2982647 10
Solid-State Relays With AC Voltage Output
Description Type Order No. Pcs./Pck.
Solid-state relay, for signal amplification and electrical isolation of the control
and load circuits, can be plugged into the SIM-AMS plug-in base, which can
be soldered, or mounted directly on the PCB with PCB connection,
input: DC voltage/output: AC voltage
OV-24DC/480AC/5 2982650 10
Accessories
Description Type Order No. Pcs./Pck.
Plug-in base SIM-AMS ... See INTERFACE catalog
Input Data ...350DC/1 ...60DC/4 ...480AC/5
Nominal input voltage U
N
24 V DC 24 V DC 24 V DC
Operating voltage range 4.25 V DC ... 32 V DC 4 V DC ... 32 V DC
Voltage switching threshold
"0" signal
"1" signal
< 1 V DC
> 3.3 V DC
< 1 V DC
> 3.3 V DC
< 1.2 V DC
> 3.5 V DC
Typical input current at U
N
15 mA 15 mA 10 mA
Typical switch-on time < 100 µs < 100 µs 1/2 period, maximum
Typical switch-off time < 250 µs < 250 µs 1/2 period, maximum
Switching frequency for ohmic nominal load 100 Hz 100 Hz 25 Hz
Output Data ...350DC/1 ...60DC/4 ...480AC/5
Nominal output voltage range 1 V DC ... 350 V DC 1 V DC ... 60 V DC 12 V AC ... 530 V AC
Periodic peak reverse voltage – – 1000 V
Limiting continuous current (see derating curves) 1 A 4 A 5 A
Minimum load current 1 mA 1 mA 20 mA
Surge current 20 A (tp = 1 s) 25 A (tp = 1 s) 80 A (tp = 20 ms)
Voltage drop at maximum limiting continuous current (2-wire) 0.5 V 0.5 V 1.2 V
Maximum load value I
2
t––50 A
2
s
Leakage current when switched off 100 µA 100 µA 1 mA
Maximum phase shift (inductive loads) – – cos ϕ = ≥ 0.5
Protective circuit Diode for protection
against polarity reversal
Diode for protection
against polarity reversal
–