271
82.5±0.3
92±0.5
(4) (4)
25±0.5
4-φ4.3±0.3
82.5±0.3
92±0.5
(10)
風吹出方向
回転方向
取付用穴
+30
300 0
リード線
AWG24
UL1007
φ102
4-φ4.5
89
89
82.5±0.3
82.5±0.3
92
mm sq.
■ Dimensions
(unit: mm)
Splash Proof Fan
92×92×25mm 〔Mass:150g〕
San Ace 92WS
IP 54
■ General Specications
・
Material
……………………
Frame: Plastics (Flammability: UL94V-0),
Impeller: Plastics (Flammability: UL94V-1)
・
Expected Life
……………
Refer to specications (Indoor, L10:Survival rate: 90% at 60
℃
,
rated voltage, and continuously run in a free air state)
・
Lead Wire
…………………⊕
red
⊖
black or blue
Sensor
yellow
・
Storage Temperature
…-
30
℃
to
+
70
℃(
Non-condensing
)
■ Specications
The following nos. have pulse sensors and ribs.
Model No.
Rated Voltage
Operating Voltage Range
Rated Current
Rated Input Rated Speed Max. Airow
Max. Static Pressure
SPL
Operating Temperature
Expected Life
[V] [V] [A] [W] [min
-1
]
[
m³/min
]
[CFM] [Pa] [inchH
²
O] [dB(A)] [℃] [h]
9WS0912H401
12 10.2 to 13.8
0.17 2.04 2,850
1.38
48.7 45.1 0.181 33
- 20 to + 70
40,000/60
℃
9WS0912F401
0.13 1.56 2,450 1.18 41.7 32.3 0.130 30
9WS0912M401
0.1 1.2 2,100 1.01 35.7 23.5 0.094 27
9WS0912L401
0.06 0.72 1,700
0.8
28.2 16.7 0.067 23
9WS0924H401
24 20.4 to 27.6
0.1 2.4 2,850
1.38
48.7 45.1 0.181 33
9WS0924F401
0.07 1.68 2,450 1.18 41.7 32.3 0.130 30
9WS0924M401
0.06 1.44 2,100 1.01 35.7 23.5 0.094 27
9WS0924L401
0.05 1.2 1,700
0.8
28.2 16.7 0.067 23
Inlet side, Outlet side
■ Reference Dimensions of Mounting Holes and Vent Opening
(unit: mm)
Rotating Direction
Airow Direction
Mounting Hole
Lead Wire
Other sensor specications are available as options. Please refer to the index (p. 513).
9WS
type