10
AT29C040A
0333IFLASH05/02
Software Data Protection
Enable Algorithm
(1)
Notes: 1. Data Format: I/O7 - I/O0 (Hex);
Address Format: A14 - A0 (Hex).
2. Data Protect state will be activated at end of
program cycle.
3. Data Protect state will be deactivated at end of
program period.
4. 256 bytes of data MUST BE loaded.
LOAD DATA AA
TO
ADDRESS 5555
LOAD DATA 55
TO
ADDRESS 2AAA
LOAD DATA A0
TO
ADDRESS 5555
LOAD DATA
TO
PAGE (256 BYTES)
(4)
WRITES ENABLED
ENTER DATA
PROTECT STATE
(2)
Software Data Protection
Disable Algorithm
(1)
LOAD DATA AA
TO
ADDRESS 5555
LOAD DATA 55
TO
ADDRESS 2AAA
LOAD DATA 80
TO
ADDRESS 5555
LOAD DATA AA
TO
ADDRESS 5555
LOAD DATA 55
TO
ADDRESS 2AAA
LOAD DATA 20
TO
ADDRESS 5555
LOAD DATA
TO
PAGE (256 BYTES)
(4)
EXIT DATA
PROTECT STATE
(3)
Software Protected Program Cycle Waveform
(1)(2)(3)
Notes: 1. A8 through A18 must specify the sector address during each high to low transition of WE (or CE) after the software code
has been entered.
2. OE
must be high when WE and CE are both low.
3. All bytes that are not loaded within the sector being programmed will be indeterminate.
11
AT29C040A
0333IFLASH05/02
Notes: 1. These parameters are characterized and not 100% tested.
2. See t
OE
spec in AC Read Characteristics.
Data Polling Waveforms
Notes: 1. These parameters are characterized and not 100% tested.
2. See t
OE
spec in AC Read Characteristics.
Toggle Bit Waveforms
(1)(2)(3)
Notes: 1. Toggling either OE or CE or both OE and CE will operate toggle bit. The t
OEHP
specification must be met by the toggling
input(s).
2. Beginning and ending state of I/O6 will vary.
3. Any address location may be used but the address should not vary.
Data Polling Characteristics
(1)
Symbol Parameter Min Typ Max Units
t
DH
Data Hold Time 10 ns
t
OEH
OE Hold Time 10 ns
t
OE
OE to Output Delay
(2)
ns
t
WR
Write Recovery Time 0 ns
Toggle Bit Characteristics
(1)
Symbol Parameter Min Typ Max Units
t
DH
Data Hold Time 10 ns
t
OEH
OE Hold Time 10 ns
t
OE
OE to Output Delay
(2)
ns
t
OEHP
OE High Pulse 150 ns
t
WR
Write Recovery Time 0 ns
12
AT29C040A
0333IFLASH05/02
Software Product Identification Entry
(1)
Software Product Identification Exit
(1)
Notes: 1. Data Format: I/O7 - I/O0 (Hex);
Address Format: A14 - A0 (Hex).
2. A1 - A18 = V
IL
.
Manufacturer Code is read for A0 = V
IL
;
Device Code is read for A0 = V
IH
.
3. The device does not remain in identification mode if
powered down.
4. The device returns to standard operation mode.
5. Manufacturer Code is 1F. The Device Code is A4.
LOAD DATA AA
TO
ADDRESS 5555
LOAD DATA 55
TO
ADDRESS 2AAA
LOAD DATA 90
TO
ADDRESS 5555
PAUSE 10 mS ENTER PRODUCT
IDENTIFICATION
MODE
(2)(3)(5)
LOAD DATA AA
TO
ADDRESS 5555
LOAD DATA 55
TO
ADDRESS 2AAA
LOAD DATA F0
TO
ADDRESS 5555
PAUSE 10 mS EXIT PRODUCT
IDENTIFICATION
MODE
(4)
Boot Block Lockout
Feature Enable Algorithm
(1)
Notes: 1. Data Format: I/O7 - I/O0 (Hex);
Address Format: A14 - A0 (Hex).
2. Lockout feature set on lower address boot block.
3. Lockout feature set on higher address boot block.
LOAD DATA AA
TO
ADDRESS 5555
LOAD DATA 55
TO
ADDRESS 2AAA
LOAD DATA 80
TO
ADDRESS 5555
LOAD DATA AA
TO
ADDRESS 5555
LOAD DATA 55
TO
ADDRESS 2AAA
LOAD DATA 40
TO
ADDRESS 5555
LOAD DATA 00
TO
ADDRESS 00000H
(2)
PAUSE 10 mS
LOAD DATA FF
TO
ADDRESS 7FFFFH
(3)
PAUSE 10 mS

AT29C040A-12PC

Mfr. #:
Manufacturer:
Microchip Technology / Atmel
Description:
NOR Flash 4M (512kx8)
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union