1.6.3 Ringing Switch, SW4
Parameter Test Conditions Symbol Minimum Typical Maximum Unit
Off-State
Leakage Current
V
SW4
(differential) = R
LINE
to R
RINGING
All-Off state.
+25 C
V
SW
(differential) = -255 V to +210 V
V
SW
(differential) = +255 V to -210 V
I
SW
-
0.05
1 A
+85 C
V
SW
(differential) = -270 V to +210 V
V
SW
(differential) = +270 V to -210 V
0.1
-40 C
V
SW
(differential) = -245 V to +210 V
V
SW
(differential) = +245 V to -210 V
0.05
On Resistance
I
SW
(on) = ±70 mA, ±80 mA R
ON
-615
On Voltage
I
SW
(on) = ± 1 mA V
ON
-1.53 V
On-State
Leakage Current
Inputs set for ringing -Measure ringing
generator current to ground.
I
RINGING
-0.10.25mA
Steady-State Current* Inputs set for ringing mode.
I
SW
- - 150 mA
Surge Current*
Ringing switches on, all other switches
off. Apply ±1 kV 10x1000 s pulse with
appropriate protection in place.
I
SW
--2A
Release Current SW4 transition from on to off.
I
RINGING
- 420 - A
Logic input to switch
output isolation
+25 C, Logic inputs = gnd,
V
SW
(R
RINGING
, R
LINE
) = ±320 V
I
SW
-
0.10
1 A
+85 C, Logic inputs = gnd,
V
SW
(R
RINGING
, R
LINE
) = ±330 V
0.12
-40 C, Logic inputs = gnd,
V
SW
(R
RINGING
, R
LINE
) = ±310 V
0.10
dV/dt sensitivity - - - 500 - V/s
*Secondary protection and current limiting must prevent exceeding this parameter.
I
NTEGRATED
C
IRCUITS
D
IVISION
8 www.ixysic.com R04
CPC7594
1.6.4 Test Switches, SW5 and SW6
Parameter Test Conditions Symbol Minimum Typical Maximum Unit
Off-State
Leakage Current
V
SW1
(differential) = T
TEST
to T
BAT
V
SW2
(differential) = R
TEST
to R
BAT
All-Off state.
+25 C,
V
SW
(differential) = -320 V to gnd
V
SW
(differential) = +260 V to -60 V
I
SW
-
0.1
1 A
+85 C,
V
SW
(differential) = -330 V to gnd
V
SW
(differential) = +270 V to -60 V
0.2
-40 C,
V
SW
(differential) = -310 V to gnd
V
SW
(differential) = +250 V to -60 V
0.1
On Resistance
I
SW
(on) = ±10 mA, ±40 mA,
R
BAT
and T
BAT
= -2 V
+25 C
R
ON
-
38 -
+85 C4670
-40 C28-
DC current limit
V
SW
(on) = ±10 V, +25 C
I
SW
- 125
-
mA
V
SW
(on) = ±10 V, +85 C
80 95
V
SW
(on) = ±10 V, -40 C
- 165 250
Dynamic current limit
(t 0.5 s)
Break switches on, all other switches
off. Apply ±1 kV 10x1000 s pulse with
appropriate protection in place.
I
SW
-2.5- A
Logic input to switch
output isolation
+25 C, Logic inputs = gnd,
V
SW
(T
LINE
, R
LINE
) = ±320 V
I
SW
-0.1
1 A
+85 C, Logic inputs = gnd,
V
SW
(T
LINE
, R
LINE
) = ±330 V
-0.3
-40 C, Logic inputs = gnd,
V
SW
(T
LINE
, R
LINE
) = ±310 V
-0.1
dV/dt sensitivity - - - 500 - V/s
I
NTEGRATED
C
IRCUITS
D
IVISION
CPC7594
R04 www.ixysic.com 9
1.7 Digital I/O Electrical Specifications
1.8 Voltage and Power Specifications
Parameter Test Conditions Symbol Minimum Typical Maximum Unit
Input Characteristics
Input voltage, Logic low Input voltage falling
V
IL
0.8 1.0 -
V
Input voltage, Logic high Input voltage rising
V
IH
1.7 2.0
Input leakage current,
IN
RINGING
and IN
TEST
,
Logic high
V
DD
= 5.5 V, V
BAT
= -75 V, V
HI
=2.4 V I
IH
-0.11A
Input leakage current,
IN
RINGING
and IN
TEST
,
Logic low
V
DD
= 5.5 V, V
BAT
= -75 V, V
IL
= 0.4 V I
IL
-0.11A
Input leakage current,
LATCH Logic high
V
DD
= 4.5 V, V
BAT
= -75 V, V
IH
= 2.4 V I
IH
719-A
LATCH Pull-up
Minimum Load
V
DD
= 4.5 V, V
BAT
= -75 V, I
IN
= -10 A
Latch input transitions to logic high.
Logic = High True
Input leakage current,
LATCH Logic low
V
DD
= 5.5 V, V
BAT
= -75 V, V
IL
= 0.4 V I
IL
- 46 125 A
Input leakage current,
T
SD
Logic high
V
DD
= 5.5 V, V
BAT
= -75 V, V
IH
= 2.4 V I
IH
10 16 30 A
Input leakage current,
T
SD
Logic low
V
DD
= 5.5 V, V
BAT
= -75 V, V
IL
= 0.4 V I
IL
10 16 30 A
Output Characteristics
Output voltage,
T
SD
Logic high
V
DD
= 5.5 V, V
BAT
= -75 V, I
TSD
= AV
TSD_off
2.4
V
DD
-V
Output voltage,
T
SD
Logic low
V
DD
= 5.5 V, V
BAT
= -75 V, I
TSD
= mA V
TSD_on
-00.4V
Parameter Test Conditions Symbol Minimum Typical Maximum Unit
Voltage Requirements
V
DD
-
V
DD
4.5 5.0 5.5 V
V
BAT
1
-
V
BAT
-19 -48 -72 V
1
V
BAT
is used only for internal protection circuitry. If V
BAT
rises above-10 V, the device will enter the all-off state and will remain in the all-off state until the battery
drops below approximately -15 V
Power Specifications
Power consumption
V
DD
= 5 V, V
BAT
= -48 V,
Measure I
DD
and I
BAT
,
Talk and All-Off States P - 5.5 10 mW
All other states P - 6.5 10 mW
V
DD
current
V
DD
= 5 V, V
BAT
= -48 V
Talk and All-Off states
I
DD
1.1 2.0 mA
Ringing and Test states
I
DD
-1.32.0mA
V
BAT
current V
DD
= 5 V, V
BAT
= -72 V, All states I
BAT
-0.110A

CPC7594BA

Mfr. #:
Manufacturer:
IXYS Integrated Circuits
Description:
Switch ICs - Various 6-pole SOIC LCAS
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet