LTC2640
19
2640fc
For more information www.linear.com/LTC2640
operation
resistor. Input and DAC register contents are not disturbed
during power-down.
The DAC can be put into power-down mode by using
command 0100. The supply current is reduced to 1.8µA
maximum (C and I grades) and the REF pin becomes HIGH
impedance (typically > 1GΩ).
Normal operation resumes after executing any command
that includes a DAC update, as shown in Table 1. The DAC
is powered up and its voltage output is updated. Normal
settling is delayed while the bias, reference, and ampli
-
fier circuits are re-enabled. When the REF pin output is
bypassed to
GND with 1nF or less, the power-up delay
time is 20µs for settling to 12-bits. This delay increases
to 200µs for 0.33µF, and 10ms for 10µF.
Voltage Output
The LTC2640’s integrated rail-to-rail amplifier has guar-
anteed load regulation when sourcing or sinking up to
10mA at 5V, and 5mA at 3V.
Load regulation is a measure of the amplifier’s ability to
maintain the rated voltage accuracy over a wide range of
load current. The measured change in output voltage per
change in forced load current is expressed in LSB/mA.
DC output impedance is equivalent to load regulation,
and
may be derived from it by simply calculating a change in
units from LSB/mA to ohms. The amplifier’s DC output
impedance is 0.1Ω when driving a load well away from
the rails.
When drawing a load current from either rail, the output
voltage headroom with respect to that rail is limited by
the 50Ω typical channel resistance of the output devices
(e.g., when sinking 1mA, the minimum output voltage is
50Ω • 1mA, or 50mV). See the graphHeadroom at Rails
vs. Output Current” in the Typical Performance Charac-
teristics section.
The amplifier is stable driving capacitive loads of up to
500pF.
Rail-to-Rail Output Considerations
In any rail-to-rail voltage output device, the output is limited
to voltages within the supply range.
Since the analog output of the DAC cannot go below ground,
it may limit the lowest codes, as shown in Figure 4b.
Similarly, limiting can
occur near full-scale when the REF
pin is tied to V
CC
. If V
REF
= V
CC
and the DAC full-scale error
(FSE) is positive, the output for the highest codes limits
at V
CC
, as shown in Figure 4c. No full-scale limiting can
occur if V
REF
is less than V
CC
– FSE.
Offset and linearity are defined and tested over the region
of the DAC transfer function where no output limiting can
occur.
Board Layout
The PC board should have separate areas for the analog and
digital sections of the circuit. A single, solid ground plane
should be used, with analog and digital signals carefully
routed over separate areas of the plane. This keeps digital
signals away from sensitive analog signals and minimizes
the interaction between digital ground currents and the
analog section of the ground plane. The resistance from
the LTC2640 GND pin to the ground plane should be as
low as possible. Resistance here will add directly to the
effective DC output impedance of the device (typically
0.1Ω). Note that the LTC2640 is no more susceptible to
this effect than any other parts of this type; on the con
-
trary, it
allows layout-based performance improvements
to shine
rather than limiting attainable performance with
excessive internal resistance.
Another technique for minimizing errors is to use a sepa-
rate power ground return trace on another board layer.
The trace should run between the point where the power
supply is connected to the board and the
DAC ground pin.
Thus the DAC ground pin becomes the common point for
analog ground, digital ground, and power ground. When
the LTC2640 is sinking large currents, this current flows
out the ground pin and directly to the power ground trace
without affecting the analog ground plane voltage.
It is sometimes necessary to interrupt the ground plane
to confine digital ground currents to the digital portion of
the plane. When doing this, make the gap in the plane only
as long as it needs to be to serve its purpose and ensure
that no traces cross over the gap.
LTC2640
20
2640fc
For more information www.linear.com/LTC2640
operation
Figure 3a. LTC2640-12 24-Bit Load Sequence (Minimum Input Word).
LTC2640-10 SDI Data Word: 10-Bit Input Code + 6 Don’t-Cares Bits;
LTC2640-8 SDI Data Word: 8-Bit Input Code + 8 Don’t-Cares Bits
Figure 3b. LTC2640-12 32-Bit Load Sequence
LTC2640-10 SDI Data Word: 10-Bit Input Code + 6 Don’t-Cares Bits;
LTC2640-8 SDI Data Word: 8-Bit Input Code + 8 Don’t-Cares Bits
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
C2 C1 C0 X X X X D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0 X X X XC3
CS/LD
SCK
SDI
COMMAND WORD 4 DON’T-CARE BITS DATA WORD
24-BIT INPUT WORD
2640 F03a
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24 25 26 27 28 29 30 31 32
C2 C1 C0 X X X X D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0 X X X XC3XXXXXXXX
CS/LD
SCK
SDI
COMMAND WORD DATA WORD
8 DON’T-CARE BITS 4 DON’T-CARE BITS
2640 F03b
32-BIT INPUT WORD
LTC2640
21
2640fc
For more information www.linear.com/LTC2640
operation
Figure 4. Effects of Rail-to-Rail Operation on a DAC Transfer Curve (Shown for 12-Bits)
(a) Overall Transfer Function
(b) Effect of Negative Offset for Codes Near Zero
(c) Effect of Positive Full-Scale Error for Codes Near Full-Scale
2640 F04
INPUT CODE
(b)
OUTPUT
VOLTAGE
NEGATIVE
OFFSET
0V
0V
2,0480 4,095
INPUT CODE
OUTPUT
VOLTAGE
(a)
V
REF
= V
CC
V
REF
= V
CC
(c)
INPUT CODE
OUTPUT
VOLTAGE
POSITIVE
FSE

LTC2640ACTS8-LM12#TRPBF

Mfr. #:
Manufacturer:
Analog Devices Inc.
Description:
Digital to Analog Converters - DAC 12-Bit, 1LSB INL SPI DAC (2.5V ref, Reset to Mid-Scale)
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment: