MODEL
ZTW1R50512 ZTW1R50515 ZTW1R51212 ZTW1R51215 ZTW1R52412 ZTW1R52415 ZTW1R54812 ZTW1R54815
MAX OUTPUT WATTAGE[W] 1.56 1.50 1.56 1.50 1.56 1.50 1.56 1.50
DC OUTPUT
VOLTAGE[V]
t
12 or +24
t
15 or +30
t
12 or +24
t
15 or +30
t
12 or +24
t
15 or +30
t
12 or +24
t
15 or +30
CURRENT[A]
0.065 0.050 0.065 0.050 0.065 0.050 0.065 0.050
SPECIFICATIONS
MODEL
ZTW1R50512 ZTW1R50515 ZTW1R51212 ZTW1R51215 ZTW1R52412 ZTW1R52415 ZTW1R54812 ZTW1R54815
INPUT
VOLTAGE[V] DC4.5 - 9 DC9 - 18 DC18 - 36 DC36 - 72
CURRENT[A]
*
1
0.466typ 0.448typ 0.183typ 0.176typ 0.092typ 0.088typ 0.046typ 0.044typ
EFFICIENCY[%]
*
1
67typ 67typ 71typ 71typ 71typ 71typ 71typ 71typ
OUTPUT
VOLTAGE[V]
t
12
(
+24
)
t
15
(
+30
)
t
12
(
+24
)
t
15
(
+30
)
t
12
(
+24
)
t
15
(
+30
)
t
12
(
+24
)
t
15
(
+30
)
CURRENT[A] 0.065 0.050 0.065 0.050 0.065 0.050 0.065 0.050
LINE REGULATION[mV] 60max 75max 60max 75max 60max 75max 60max 75max
LOAD REGULATION[mV] 600max 750max 600max 750max 600max 750max 600max 750max
RIPPLE[mVp-p]
*
2
120max 120max 120max 120max 120max 120max 120max 120max
RIPPLE NOISE[mVp-p]
*
2
150max 150max 150max 150max 150max 150max 150max 150max
TEMPERATURE REGULATION[mV]
-20 to +55
C
150max 180max 150max 180max 150max 180max 150max 180max
DRIFT[mV]
*
3
50max 60max 50max 60max 50max 60max 50max 60max
START-UP TIME[ms] 20max
(
Minimum input
,
Io=100%
)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
Fixed
OUTPUT VOLTAGE SETTING[V]
11.40 - 12.60 14.25 - 15.75 11.40 - 12.60 14.25 - 15.75 11.40 - 12.60 14.25 - 15.75 11.40 - 12.60 14.25 - 15.75
PROTECTION
CIRCUIT
OVERCURRENT PROTECTION
Works over 105% of rating and recovers automatically
ISOLATION
INPUT-OUTPUT AC500V 1minute
,
Cutoff current = 10mA
,
DC500V 50M
W
min
(
20
t
15
C
)
INPUT-CASE AC500V 1minute
,
Cutoff current = 10mA
,
DC500V 50M
W
min
(
20
t
15
C
)
OUTPUT-CASE AC500V 1minute
,
Cutoff current = 10mA
,
DC500V 50M
W
min
(
20
t
15
C
)
ENVIRONMENT
OPERATING TEMP.
,
HUMID.AND ALTITUDE
-20 to +71
C
,
20 - 95%RH
(
Non condensing
)(
Refer to DERATING CURVE
),
3
,
000m
(
10
,
000feet
)
max
STORAGE TEMP.
,
HUMID.AND ALTITUDE
-40 to +85
C
,
20 - 95%RH
(
Non condensing
),
9
,
000m
(
30
,
000feet
)
max
VIBRATION 10 - 55Hz
,
98.0m/s
2
(
10G
),
3minutes period
,
60minutes each along X
,
Y and Z axis
IMPACT 490.3m/s
2
(
50G
),
11ms
,
once each X
,
Y and Z axis
SAFETY AGENCY APPROVALS UL60950-1
,
C-UL
,
EN60950-1 Complies with IEC60950-1
OTHERS
CASE SIZE/WEIGHT 28
X
21
X
10mm
(
W
X
H
X
D
)
/ 15g max
COOLING METHOD Convection
Output pins can be connected in series to make a 24V/30V output.