F03-02 SUS304

CSM_F03-__DS_E_8_1
1
Electrodes and Accessories
F03-@
A Wide Variety of Electrodes for Long
Lasting Reliability
Standard Electrodes are made of stainless steel (SUS 304) and
can be used in applications for purified water.
• SUS316 Electrodes can be used in applications where
resistance to corrosion is required. Titanium and Hastelloy
Electrodes can be used in applications where resistance to acid
is required.
• For applications where long electrodes are required, a
connection nut and two Lock Nuts can be used to extend the
electrodes 1 m at a time.
Refer to Safety Precautions for Electrodes and
Electrode Holders.
Ordering Information
Material indications are provided on all OMRON electrodes, connection nuts, and Lock Nuts.
Electrodes
Select an electrode appropriate for the type of liquid. Refer to Technical Guide for Level Controllers.
Note: 1. HAS: HALSTELLOY is a registered trademark of Haynes International, Inc.
2. UNS No. (Unified Numbering System No.) is an international metal designation system that specifies a unique number for each material.
Insulated Electrodes
Electrodes are insulated with a plastic sheath to prevent them from
touching each other and to isolate them from debris in the liquid.
Before application, strip back about 10 cm of the sheath at the end to
ensure sufficient conductivity.
Note: Tubing comes in 1-m lengths with a sheath thickness of
0.5 mm.
Connecting Nuts
Note: UNS No. (Unified Numbering System No.) is an international
metal designation system that specifies a unique number for
each material.
Model Material Weight (g) Material indication lines
F03-01 SUS304 SUS304 Approx. 170 1 line
F03-01 SUS316 SUS316 2 lines
F03-01 HAS B (See note 1.) N10665 (See note 2.) Approx. 195 3 lines
F03-01 HAS C (See note 1.) N10276 (See note 2.) Approx. 190 4 lines
F03-01 TITANIUM Titanium Approx. 100 5 lines
Electrodes
M6
Material
indication
lines
Model
F03-01 SUS304 Vinyl Tubing
F03-01 SUS304 Fluororesin Tubing
F03-01 SUS316 Vinyl Tubing
F03-01 SUS316 Fluororesin Tubing
Model Material Weight (g) Material
indication
F03-02 SUS304 SUS303
(Equivalent to SUS304)
Approx. 12 Blank
F03-02 SUS316 SUS316 6
F03-02 HAS B N10665 (See note.) Approx. 20 B
F03-02 HAS C N10276 (See note.) C
F03-02 TITANIUM Titanium Approx. 6 T
F03-@
2
Electrode Sets
An Electrode Set consists of an electrode, a connecting nut, and two
Lock Nuts.
Note: Hastelloy and titanium Electrodes do not come in sets.
Lock Nuts
Note: 1. Only SUS304 and SUS316 Lock Nuts come with spring
washers made of the same material. HAS B, HAS C and
TITANIUM don’t come with spring washer.
2. UNS No. (Unified Numbering System No.) is an internation-
al metal designation system that specifies a unique number
for each material.
Electrode Separators
When long electrodes are required, use Separators at each joint (every 1 m) to prevent the Electrodes from touching each other.
Use a 1-pole Separator with BF Electrode Holders. The five-pole model can be used with PS-5S and PS-4S Electrode Holders.
Separators cannot be used with PS-31 Electrode Holders.
Note: The Electrode Separators cannot be used unless the Electrodes are coupled.
Accessories (Order Separately)
Set model Components No. of parts
in an set
Weight
(g)
F03-60 SUS304 F03-01 SUS304 1 Approx.
190
F03-02 SUS304 1
F03-03 SUS304 2
F03-60 SUS316 F03-01 SUS316 1
F03-02 SUS316 1
F03-03 SUS316 2
Model Material Weight
(g)
Material
indication
F03-03 SUS304
(See note 1.)
SUS303
(Equivalent to SUS304)
Approx.
2
Blank
F03-03 SUS316
(See note 1.)
SUS316 6
F03-03 HAS B N10665
(See note 2.)
Approx.
5
B
F03-03 HAS C N10276
(See note 2.)
C
F03-03 TITANIUM Titanium Approx.
2
T
Model No. of
Electrodes
Dimensions Applicable
Electrode
Holder
Weight (g) Material Operating
Temperature
F03-14 1P 1 BF-@(R) Approx. 15 Ceramic 250°C max.
F03-14 3P 3 PS-3S(R) Approx. 30
F03-14 5P 5 PS-4S(R)
PS-5S(R)
6.5 dia.
28 dia.
Electrode
Holder
Separator
Connecting
nut
Lock Nut
Lock Nut
Separator
Lock
Nut
Electrode
Spring
washer
Connecting
nut
Note: When using two or more Separators,
be careful with the mounting direction
of the connecting nut screws which
connect electrodes. Avoid the screws
from touching each other.
Three, 7-dia. holes
41
20
Five, 7-dia.
holes
20
46
Application Model
Protective Cover (for PS-@S and BF-3/-5) F03-11
Mounting Frame (for PS-@S) F03-12
Mounting Frame for Installing in Concrete (for PS-@S) F03-13
Dust-proof Rubber Cap (for PS-31) F03-31
F03-@
3
Dimensions of Electrodes and Accessories
Note: All units are in millimeters unless otherwise indicated.
Safety Precautions
Refer to Safety Precautions for All Level Controllers.
Precautions for Correct Use
Cleaning Electrodes
Electrodes are clean when they are dispatched. In the rare occasion
that they become dirty during transit or storage, such as forming an
oil film on the surface, clean them again before using them.
Operating Environment
Use the Electrode within the ambient operating temperature range of
the Holder.
Standard: 1 m
Threaded section: 21±2
M6
M6
5.23 dia.
Threaded section: 21±2
11.5
10
5
M6
M6
13
10 5.5
Electrode
F03-01
Lock Nut
F03-03
SUS304
SUS316
Titanium
F03-03
HAS B
HAS C
11.5
20
(15) (See note 1.)
10
M6
M6
13
10 20
(See note 2.)
11.5
20
(See note 2.)
M6
10
Connecting nut
F03-02
SUS304
SUS316
F03-02
HAS B
HAS C
F03-02
Titanium
Note: 1. Dimension when mounting Electrodes.
2. Clamp screws are not provided for Hastelloy B, Hastelloy C, or titanium models. F03-03 Lock Nuts are used to mount Electrodes.
In the interest of product improvement, specifications are subject to change without notice.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.

F03-02 SUS304

Mfr. #:
Manufacturer:
Omron Automation and Safety
Description:
Controllers CONNECTING NUT
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union