Return Loss (RL)
Frequency [MHz] Min. Structural Return Loss (SRL)
5-1000 MHz 20 dB
Delay
Nominal Delay Nominal Velocity of Propagation (VP) [%]
1.2 ns/ft 83 %
High Freq
Frequency [MHz] Max. Insertion Loss (Attenuation)
5 MHz 0.58 dB/100ft
55 MHz 1.60 dB/100ft
211 MHz 3.05 dB/100ft
270 MHz 3.37 dB/100ft
300 MHz 3.55 dB/100ft
350 MHz 3.85 dB/100ft
400 MHz 4.15 dB/100ft
450 MHz 4.40 dB/100ft
550 MHz 4.90 dB/100ft
750 MHz 5.65 dB/100ft
870 MHz 6.11 dB/100ft
1000 MHz 6.55 dB/100ft
Voltage
UL Voltage Rating
350 V RMS
Temperature Range
Operating Temp Range: -30°C To +80°C
Mechanical Characteristics
Bulk Cable Weight: 29 lbs/1000ft
Max Recommended Pulling Tension: 126 lbs
Min Bend Radius/Minor Axis: 2.75 in
Standards
NEC/(UL) Specification: CATVR, CMG, CMR
RG Type: 6/U Type
Series Type: Series 6
RG / Series Type: Series 6
Applicable Environmental and Other Programs
EU Directive 2000/53/EC (ELV): Yes
EU Directive 2003/96/EC (BFR): Yes
EU Directive 2011/65/EU (ROHS II): Yes
EU Directive 2012/19/EU (WEEE): Yes
EU Directive Compliance: EU Directive 2003/11/EC (BFR)
EU CE Mark: No
EU RoHS Compliance Date (yyyy-mm-dd): 2004-01-01
CA Prop 65 (CJ for Wire & Cable): Yes
MII Order #39 (China RoHS): Yes
Suitability
Suitability - Indoor: Yes
Flammability, LS0H, Toxicity Testing
UL Flammability: UL1666 Vertical Riser
CSA Flammability: FT4
UL voltage rating: 350 V RMS