Twin SLIC Protector
http://www.littelfuse.com 2 - 44 © 2004 Littelfuse, Inc.
+1 972-580-7777 SIDACtor
®
Data Book and Design Guide
Twin SLIC Protector
Subscriber Line Interface Circuits (SLIC) are highly susceptible to transient voltages, such
as lightning and power cross conditions. To minimize this threat, Littelfuse provides this
dual-chip, fixed-voltage SLIC protector device.
For specific design criteria, see details in Figure 3.29.
* For surge ratings, see table below.
General Notes:
• All measurements are made at an ambient temperature of 25 °C. I
PP
applies to -40 °C through +85 °C temperature range.
• I
PP
is a repetitive surge rating and is guaranteed for the life of the product.
• V
DRM
is measured at I
DRM.
• V
S
and V
F
are measured at 100 V/µs.
• Special voltage (V
S
and V
DRM
) and holding current (I
H
) requirements are available upon request.
• Off-state capacitance (C
O
) is measured across pins 1-2 or 3-2 at 1 MHz with a 2 V bias. Capacitance across pins 1-3 is
approximately half.
• Parallel capacitive loads may affect electrical parameters.
• Compliance with GR 1089 or UL 60950 power cross tests may require special design considerations. Contact the factory for further
information.
Electrical Parameters
Part
Number *
V
DRM
Volts
V
S
Volts
V
T
Volts
V
F
Volts
I
DRM
µAmps
I
S
mAmps
I
T
Amps
I
H
mAmps
C
O
pFPins 1-2, 3-2
P0641CA2 58 77 4 5 5 800 1 120 60
P0721CA2 65 88 4 5 5 800 1 120 60
P0901CA2 75 98 4 5 5 800 1 120 60
P1101CA2 95 130 4 5 5 800 1 120 60
P1701CA2 160 200 4 5 5 800 1 120 70
Surge Ratings (Preliminary Data)
Series
I
PP
2x10 µs
Amps
I
PP
8x20 µs
Amps
I
PP
10x160 µs
Amps
I
PP
10x560 µs
Amps
I
PP
10x1000 µs
Amps
I
TSM
60 Hz
Amps
di/dt
Amps/µs
A 150 150 90 50 45 20 500
1
3
2
(T)
(G)
(R)