FN2010-30-17

DATASHEET
Single-Stage Filters FN 2010
General Purpose AC/DC EMI Filter
Rated currents from 1 to 60 A
General purpose filtering performance
Optional medical versions (B type)
Optional safety versions (A type)
Optional enhanced performance versions
Optional DC optimized versions
Performance indicators
Technical specifications
Rated voltage*
250 VAC, 50/60 Hz; 250 VDC
Operating frequency
DC to 400 Hz
Rated currents
1 to 60 A @ 40°C max.
High potential test voltage
P –> PE 2000 VAC for 2 sec (equiv. cap <88 nF)
P –> PE 2550 VDC for 2 sec (equiv. cap >88 nF)
P –> PE 2500 VAC for 2 sec (B types)
P –> N 1100 VDC for 2 sec
Temperature range (operation and storage)
-25 °C to +100 °C (25/100/21)
Certified to
UL 1283, CSA 22.2 No. 8 1986, IEC/EN 60939 (applies to
AC and DC applications)
Flammability corresponding to
UL 94 V-2 or better
MTBF @ 40°C/230 V (Mil-HB-217F)
1,250,000 hours
3,200,000 hours (B types)
*maximum RMS operating voltage at rated frequency or the maximum DC operating voltage
Approvals
Features and benefits
FN 2010 filters are designed for easy and fast chassis
mounting
FN 2010 filters are available as B versions without Y-
capacitors for medical applications as well as A
version with low capacitance for safety critical
applications with necessity for low leakage currents
FN 2010 filters are also available as enhanced
performance and DC optimized versions. With
higher attenuation in very compact housing (M,
N1,N types)
All filters provide a general purpose conducted
attenuation performance, based on chokes with
high saturation resistance and excellent thermal
behavior
FN 2010 filters can be used to cover a broad range
of usage and they offer a good size/amperage ratio
Various terminal options allow you to select the
desired connection style
Typical applications
Electrical and electronic equipment
Consumer goods
Household equipment
Medical equipment
Office automation equipment
Datacom equipment
Typical electrical schematic
2 EMC/EMI Products Schaffner Group Datasheets 2017
Filter selection table
Filter* Rated current Leakage current** Inductance Capacitance Resistance Input/Output Weight
@ 40°C (25°C) @ 250 VAC/50 Hz L Cx Cy R connections
(@ 120 VAC/60 Hz)
[A] [mA] [mH] [μF] [nF] [kΩ]
[g]
FN 2010-1-.. 1 (1.15) 0.66 (0.38) 12 0.1 4.7 1000 -06 -07 65
FN 2010-3-.. 3 (3.45) 0.66 (0.38) 2.5 0.1 4.7 1000 -06 -07 65
FN 2010-6-.. 6 (6.9) 0.66 (0.38) 1 0.1 4.7 1000 -06 -07 65
FN 2010-10-.. 10 (11.5) 0.66 (0.38) 0.8 0.1 4.7 1000 -06 -07 85
FN 2010-12-.. 12 (13.8) 0.66 (0.38) 0.7 0.1 4.7 1000 -06 -07 85
FN 2010-16-.. 16 (18.4) 0.66 (0.38) 0.7 0.1 4.7 1000 -06 -07 140
FN 2010-20-.. 20 (23) 0.66 (0.38) 0.6 0.1 4.7 1000 -06 -07 -08 210
FN 2010-30-08 30 (34.5) 0.79 (0.46) 0.7 0.47 10 1000 -08 470
FN 2010-60-24 60 (69) 0.79 (0.46) 1 1.5 10 330 -24 1100
FN 2010 A-1-.. 1 (1.15) 0.07 (0.04) 12 0.1 0.47 1000 -06 -07 65
FN 2010 A-3-.. 3 (3.45) 0.07 (0.04) 2.5 0.1 0.47 1000 -06 -07 65
FN 2010 A-6-.. 6 (6.9) 0.07 (0.04) 1 0.1 0.47 1000 -06 -07 65
FN 2010 A-10-.. 10 (11.5) 0.07 (0.04) 0.8 0.1 0.47 1000 -06 -07 85
FN 2010 A-12-.. 12 (13.8) 0.07 (0.04) 0.7 0.1 0.47 1000 -06 -07 85
FN 2010 A-16-.. 16 (18.4) 0.07 (0.04) 0.7 0.1 0.47 1000 -06 -07 140
FN 2010 A-20-.. 20 (23) 0.07 (0.04) 0.6 0.1 0.47 1000 -06 -07 -08 210
FN 2010 A-30-08 30 (34.5) 0.07 (0.04) 0.7 0.47 0.47 1000 -08 470
FN 2010 A-60-24 60 (69) 0.07 (0.04) 1 1.5 0.47 330 -24 1100
FN 2010 B-1-.. 1 (1.15) 0.00 12 0.1 1000 -06 -07 65
FN 2010 B-3-.. 3 (3.45) 0.00 2.5 0.1 1000 -06 -07 65
FN 2010 B-6-.. 6 (6.9) 0.00 1 0.1 1000 -06 -07 65
FN 2010 B-10-.. 10 (11.5) 0.00 0.8 0.1 1000 -06 -07 85
FN 2010 B-12-.. 12 (13.8) 0.00 0.7 0.1 1000 -06 -07 85
FN 2010 B-16-.. 16 (18.4) 0.00 0.7 0.1 1000 -06 -07 140
FN 2010 B-20-.. 20 (23) 0.00 0.6 0.1 1000 -06 -07 -08 210
FN 2010 B-30-08 30 (34.5) 0.00 0.7 0.47 1000 -08 470
FN 2010 B-60-24 60 (69) 0.00 1 1.5 330 -24 1100
Enhanced performance
FN 2010 N1-1-06 1 (1.15) 5.34 (3.08) 12 0.1 68 1000 -06 70
FN 2010 N1-3-06 3 (3.45) 5.34 (3.08) 2.5 0.1 68 1000 -06 70
FN 2010 N1-6-06 6 (6.9) 5.34 (3.08) 1 0.1 68 1000 -06 70
FN 2010 N1-10-06 10 (11.5) 5.34 (3.08) 0.8 0.1 68 1000 -06 85
FN 2010 N1-12-06 12 (13.8) 3.69 (2.13) 0.7 0.1 47 1000 -06 85
FN 2010 M-16-06 16 (18.4) 3.69 (2.13) 0.7 0.1 47 1000 -06 140
FN 2010 M-20-.. 20 (23) 3.69 (2.13) 0.6 0.1 47 1000 -06 -08 220
FN 2010 N-30-08 30 (34.5) 7.85 (4.52) 0.7 0.47 100 1000 -08 400
FN 2010 N-60-24 60 (69) 7.85 (4.52) 1 1.5 100 330 -24 1120
*
* To compile a complete part number, please replace the -.. with the required I/O connection style (e.g. FN 2010-30-08, FN 2010B-10-06). The different letters code the
used Cy values in the filter type (A = 0.47nF; M = 47nF; N1 = 47nF; N = 100nF)
** Maximum leakage under usual AC operating conditions (acc. IEC 60939-3). Note: if the neutral line is interrupted, worst case leakage could reach twice this level.
3 EMC/EMI Products Schaffner Group Datasheets 2017
Typical filter attenuation
Per CISPR 17; A=50 Ω/50 Ω sym; B=50 Ω/50 Ω asym
Standard types
1 and 3 A types
6 to 12 A types
16 and 20 A types
30 and 60 A types
Enhanced performance types
1 A types
3 A types
6 A types
10 and 12 A types
16 A types
20 A types
30 A types
60 A types
Product Selector

FN2010-30-17

Mfr. #:
Manufacturer:
Schaffner
Description:
Power Line Filters 30A GENERAL PURPOSE FLTR
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union