DATA SHEET • SKY65450-92LF: 40 MHz TO 1 GHz BROADBAND 75 Ω CATV LNA WITH BYPASS MODE
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
2 November 14, 2017 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 203094H
Table 1. SKY65450-92LF Signal Descriptions
Pin Name Description Pin Name Description
1 RFOUT RF output 4 Bypass CTRL
Bypass CTRL (0 = bypass mode, 1 = gain
mode, floating = gain mode)
2 VCC Source voltage 5 GND Ground
3 NC Not connected 6 RFIN RF input
Technical Description
The SKY65450-92LF is a single-stage, low-noise amplifier with a
bypass switch that operates with a single 3.3 V power supply
connected through an RF choke (inductor L1) to the output signal
(pin 1). The bias current is set by the R1 external resistor. The
device is internally RF-matched and only requires input and out
blocking capacitors C1 and C2 to operate over a frequency range
of 40 MHz to 1 GHz.
Electrical and Mechanical Specifications
The absolute maximum ratings of the SKY65450-92LF are
provided in Table 2. The recommended operating conditions are
specified in Table 3, and electrical specifications are provided in
Table 4.
Table 2. SKY65450-92LF Absolute Maximum Ratings
1
Parameter Symbol Minimum Maximum Units
RF input power PIN +20 dBm
Supply voltage VCC 1.4 3.6 V
Logic high voltage VHIGH VCC V
Storage temperature TSTG -55 +125 C
Junction temperature TJ +125 C
Electrostatic discharge:
Human Body Model (HBM), Class 1C
Charged-Device Model (CDM), Class C3
ESD
1500
1500
V
V
1
Exposure to maximum rating conditions for extended periods may reduce device reliability. There is no damage to device with only one parameter set at the limit and all other parameters
set at or below their nominal value. Exceeding any of the limits listed here may result in permanent damage to the device.
ESD HANDLING: Although this device is designed to be as robust as possible, electrostatic discharge (ESD) can damage this device.
This device must be protected at all times from ESD when handling or transporting. Static charges may easily produce
potentials of several kilovolts on the human body or equipment, which can discharge without detection.
Industry-standard ESD handling precautions should be used at all times.
Table 3. SKY65450-92LF Recommended Operating Conditions
Parameter Symbol Min Typ Max Units
Frequency f 40 1000 MHz
Supply 3.1 3.3 3. 5 V
Logic high voltage VIH 1.4 VCC V
Logic low voltage VIL 0 0.7 V
Ambient temperature -40 +85 C