INDUSTRIAL TEMPERATURE RANGE
IDT74FCT157AT/CT/DT
FAST CMOS QUAD 2-INPUT MULTIPLEXER
3
Symbol Parameter Test Conditions
(1)
Min. Typ.
(2)
Max. Unit
VIH Input HIGH Level Guaranteed Logic HIGH Level 2 — — V
VIL Input LOW Level Guaranteed Logic LOW Level — — 0.8 V
IIH Input HIGH Current
(4)
VCC = Max. VI = 2.7V — — ±1µA
IIL Input LOW Current
(4)
VCC = Max. VI = 0.5V — — ±1µA
I
OZH High Impedance Output Current
(4)
VCC = Max., VI = VCC (Max.) VI = 2.7V — — ±1µA
IOZL VI = 0.5V — — ±1
II Input HIGH Current
(4)
VCC = Max., VI = VCC (Max.) — — ±1µA
VIK Clamp Diode Voltage VCC = Min., IIN = –18mA — –0.7 –1.2 V
VH Input Hysteresis — — 200 — mV
I
CC Quiescent Power Supply Current VCC = Max. — 0.01 1 mA
V
IN = GND or VCC
DC ELECTRICAL CHARACTERISTICS OVER OPERATING RANGE
Following Conditions Apply Unless Otherwise Specified:
Industrial: TA = –40°C to +85°C, VCC = 5.0V ±5%
NOTES:
1. For conditions shown as Min. or Max., use appropriate value specified under Electrical Characteristics for the applicable device type.
2. Typical values are at VCC = 5.0V, +25°C ambient.
3. Not more than one output should be tested at one time. Duration of the test should not exceed one second.
4. The test limit for this parameter is ±5µA at TA = –55°C.
5. This parameter is guaranteed but not tested.
Symbol Parameter Test Conditions
(1)
Min. Typ.
(2)
Max. Unit
V
OH Output HIGH Voltage VCC = Min IOH = –8mA 2.4 3.3 — V
VIN = VIH or VIL IOH = –15mA 2 3 —
VOL Output LOW Voltage VCC = Min IOL = 48mA — 0.3 0.5 V
VIN = VIH or VIL
IOS Short Circuit Current VCC = Max., VO = GND
(3)
–60 –120 –225 mA
IOFF Input/Output Power Off Leakage
(5)
VCC = 0V, VIN or VO
≤≤
≤≤
≤
4.5V — — ±1µA
OUTPUT DRIVE CHARACTERISTICS