120 PCB Relay G5T
■ Contact Ratings
*P level: λ
60
= 0.1 X 10
-6
/operation
■ Characteristics
Note: 1. Data shown above are of initial value.
2. Please avoid ultrasonic cleaning this relay.
■ Approvals
UL Recognized (File No. E41515) / CSA Certified (File No. 1527954) - - Ambient Temp. = 40°C
VDE0435 (EN61810-1)
CQC (license No. 04001010419)
Rated load (resistive) 5 A at 250 VAC
5 A at 30 VDC
Rated carry current 5 A
Max. switching voltage 250 VAC, 30 VDC
Max. switching current 5 A
Max. switching capacity 1250 VA, 150 W
Minimum Permissible Load* 10 mA at 5 VDC
Contact resistance 100 mΩ max. (measured by voltage drop method using 1 A @ 5 VDC)
Operate time 10 ms max.
Release time 10 ms max.
Insulation resistance 1,000 MΩ min. (at 500 VDC)
Dielectric strength 4,000 VAC, 50/60 Hz for 1 min. between coil and contacts
750 VAC, 50/60 Hz for 1 min. between contacts of same polarity
Vibration resistance Destruction 10 to 55 Hz, 1.5 mm double amplitude
Malfunction 10 to 55 Hz, 1.5 mm double amplitude
Shock resistance Destruction
1,000 m/s
2
(approx.100 G)
Malfunction
100 m/s
2
(approx. 10 G)
Service Life Mechanical 2,000,000 operations min. (at 18,000 operations/hr)
Electrical
(resistive load)
100,000 operations min. (3 A at 250 VAC, 30 VDC)
30,000 operations min. (5 A at 250 VAC, 30 VDC)
(at 1,800 operations/hr)
Ambient operating temperature -40°C to 70°C (with no icing or condensation)
Ambient operating humidity 5% to 85%
Weight Approx. 3 g
Model Coil rating Contact rating
G5T-1A 5, 12, 24 VDC 5 A, 250 VAC (resistive), 6,000 cycles
5 A, 30 VDC (resistive), 6,000 cycles
Model Coil rating Contact rating
G5T-1A 5,12, 24 VDC 5 A, 250 VAC (cosφ = 1) 10,000 cycles
5 A, 30 VDC (L/R = 0 ms) 10,000 cycles
3 A, 250 VAC (cosφ = 1) 100,000 cycles
Model Coil rating Contact rating
G5T-1A 5,12, 24 VDC 5 A, 250 VAC resistive,10,000 cycles
5 A, 30 VAC resistive,10,000 cycles