MAX6457–MAX6460
19-2048; Rev 6; 12/12
For pricing, delivery, and ordering information, please contact Maxim Direct
at 1-888-629-4642, or visit Maxim’s website at www.maximintegrated.com.
High-Voltage, Low-Current Voltage Monitors in
SOT Packages
General Description
The MAX6457–MAX6460 high supply voltage, low-power
voltage monitors operate over a 4V to 28V supply voltage
range. Each device includes a precision bandgap refer-
ence, one or two low-offset voltage comparators, internal
threshold hysteresis, power-good or reset timeout
options, and one or two high-voltage open-drain outputs.
Two external resistors (three for window detection) set the
trip threshold voltages.
The MAX6457 is a single voltage monitor for undervoltage
or overvoltage detection. A logic-based clear input either
latches the output for overvoltage applications or allows
the device to operate in transparent mode. The MAX6458
includes two comparators (one overvoltage and one
undervoltage) for window detection and a single output to
indicate if the monitored input is within an adjustable volt-
age window. The MAX6459 includes dual overvoltage/
undervoltage comparators with two independent com-
parator outputs. Use the MAX6459 as a window com-
parator with separate undervoltage and overvoltage
outputs or as two independent, single voltage monitors.
The MAX6460 includes a single comparator and an inter-
nal reference, and can also accept an external reference.
The inverting and noninverting inputs of the comparator
are externally accessible to support positive or negative
voltage monitors and to configure the device for active-
high or active-low output logic.
The MAX6457/MAX6458 offer fixed timing options as a
voltage detector with a 50µs typical delay or as a reset cir-
cuit with a 90ms minimum reset timeout delay. The moni-
tored input must be above the adjusted trip threshold (or
within the adjusted voltage window for the MAX6458) for
the selected timeout period before the output changes
state. The MAX6459/MAX6460 offer only a fixed 50µs
timeout period. Internal threshold hysteresis options (0.5%,
5%, and 8.3% for the MAX6457/MAX6458/MAX6459, and
0.5% for the MAX6460) reduce output chatter in noise-
sensitive applications. Each device is available in a small
SOT23 package and specified over the extended temper-
ature range of -40°C to +125°C.
Applications
Undervoltage Monitoring/Shutdown
Overvoltage Monitoring/Protection
Window Voltage Detection Circuitry
Multicell Battery-Stack Powered Equipment
Notebooks, eBooks
Automotive
Industrial
Telecom
Networking
Features
o Wide Supply Voltage Range, 4V to 28V
o Internal 2.25V ±2.5% Reference
o Low Current (3.5µA, typ at 12V)
o Open-Drain n-Channel Output (28V Compliant)
o Internal Threshold Hysteresis Options
(0.5%, 5%, 8.3%)
o Two IN-to-OUT Timeout Period Options
(50µs, 150ms)
o Internal Undervoltage Lockout
o Immune to Short Voltage Transients
o Small SOT23 Packages
o Few External Components
o Fully Specified from -40°C to +125°C
Ordering Information
5-CELL
Li+
BATTERY
STACK
BATTERY
CHARGER
DC-DC
CONVERTER
LOAD
R1
R2
R
PULLUP
SHDN
+21V (NOMINAL)
V
CC
GND CLEAR
IN+ OUT
MAX6457
IN
OUT
Typical Operating Circuit
Pin Configurations appear at end of data sheet.
PART TEMP RANGE PIN-PACKAGE
MAX6457UKD_ _-T -40°C to +125°C
5 SOT23
MAX6458UKD_ _-T -40°C to +125°C
5 SOT23
MAX6459UT_-T -40°C to +125°C
6 SOT23
MAX6459UT_/V+ -40°C to +125°C
6 SOT23
MAX6460UT-T -40°C to +125°C
6 SOT23
Note: The MAX6457/MAX6458/MAX6459 are available with
factory-trimmed internal hysteresis options. The MAX6457 and
MAX6458 offer two fixed timing options. Select the desired hys-
teresis and timing options using Table 1 or the Selector Guide at
the end of the data sheet, and enter the corresponding letters
and numbers in the part number by replacing “_ _” or “_”. These
devices are offered in tape-and-reel only and must be ordered in
2500-piece increments.
Devices are available in both leaded and lead(Pb)-free/RoHS-
compliant packaging. Specify lead(Pb)-free by replacing “-T”
with “+T” when ordering.
/V denotes an automotive qualified part.
MAX6457–MAX6460
High-Voltage, Low-Current Voltage Monitors in
SOT Packages
2
Maxim Integrated
ABSOLUTE MAXIMUM RATINGS
ELECTRICAL CHARACTERISTICS
(V
CC
= 4V to 28V, T
A
= -40°C to +125°C, unless otherwise specified. Typical values are at T
A
= +25°C.) (Note 1)
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional
operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to
absolute maximum rating conditions for extended periods may affect device reliability.
V
CC
, OUT, OUTA, OUTB, CLEAR to GND ..........-0.3V to +30.0V
IN+, IN- to GND..........................................-0.3V to (V
CC
+ 0.3V)
REF to GND..............-0.3V to the lower of +6V and (V
CC
+ 0.3V)
Input Currents (V
CC
, IN+, IN-) ............................................20mA
Sink Current (OUT, OUTA, OUTB) ......................................20mA
Continuous Power Dissipation (T
A
= +70°C)
5-Pin SOT23 (derate 7.1 mW/°C above +70°C)............571mW
6-Pin SOT23 (derate 8.7 mW/°C above +70°C)............696mW
Junction Temperature......................................................+150°C
Operating Temperature Range .........................-40°C to +125°C
Storage Temperature Range .............................-65°C to +150°C
Lead Temperature (soldering, 10s) .................................+300°C
Soldering Temperature (reflow)
Lead(Pb)-free................................................................+260°C
Containing lead (Pb) .....................................................+240°C
PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS
Operating Voltage Range V
CC
(Note 2) 4 28 V
V
CC
= 5V, no load 2 5
V
CC
= 12V, no load 3.5 7.5Supply Current I
CC
V
CC
= 24V, no load 6.5 12.5
µA
T
A
= -40°C to +85°C, V
CC
4V 1.195 1.228 1.255
V
TH+
V
IN
rising
T
A
= +85°C to +125°C, V
CC
4V 1.170 1.255
T
A
= -40°C to +85°C 1.180 1.255
MAX645_U_D_A
T
A
= +85°C to +125°C 1.155 1.255
T
A
= -40°C to +85°C 1.133 1.194
MAX645_U_D_B
T
A
= +85°C to +125°C 1.111 1.194
T
A
= -40°C to +85°C 1.093 1.151
Threshold Voltage
V
TH-
V
IN
falling
MAX645_U_D_C
T
A
= +85°C to +125°C 1.071 1.151
V
MAX64_ _U_D_A 0.5
MAX64_ _U_D_B 5Threshold Voltage Hysteresis
MAX64_ _U_D_C 8.3
%V
TH+
IN Operating Voltage Range V
IN
(Note 2) 0 V
CC
V
IN Leakage Current I
IN
V
IN
= 1.25V, V
CC
= +28V -55 +55 nA
MAX645_UKD0_
MAX6459UT_
MAX6460UT
50 µs
OUT Timeout Period t
TP
MAX6457 and MAX6458 only,
D3 option
90 150 210 ms
Startup Time
V
CC
rising from GND to V
CC
4V in less than
1µs (Note 3)
2ms
V
IL
0.4
CLEAR Input Logic Voltage
(MAX6457)
V
IH
2
V
MAX6457–MAX6460
High-Voltage, Low-Current Voltage Monitors in
SOT Packages
3
Maxim Integrated
Note 1: Devices are production tested at T
A
= +25°C. Overtemperature limits are guaranteed by design.
Note 2: IN voltage monitoring requires that V
CC
4V, but OUT remains asserted in the correct undervoltage lockout state for V
CC
down to 1.5V.
Note 3: Startup time is the time required for the internal regulator and reference to reach specified accuracy after the monitor is
powered up from GND.
Note 4: The open-drain output can be pulled up to a voltage greater than V
CC
but cannot exceed +28V.
ELECTRICAL CHARACTERISTICS (continued)
(V
CC
= 4V to 28V, T
A
= -40°C to +125°C, unless otherwise specified. Typical values are at T
A
= +25°C.) (Note 1)
PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS
V
CC
1.5V, I
SINK
= 250µA, OUT asserted,
T
A
= -40°C to +85°C
0.4
Output Voltage Low V
OL
V
CC
4.0V, I
SINK
= 1mA, OUT asserted,
T
A
= -40°C to +125°C
0.4
V
Output Leakage Current I
LKG
V
CC
= 5V, V
OUT
= 28V (Note 4) 500 nA
Output Short-Circuit Sink
I
SC
OUT asserted, OUT = V
CC
10 mA
MAX6460
Reference Short-Circuit Current REF = GND 7 mA
T
A
= -40°C to +85°C 2.183 2.25 2.303
Reference Output Voltage V
REF
T
A
= +85°C to +125°C 2.171 2.25 2.303
V
Load Regulation
Sourcing: 0 I
REF
100µA,
sinking: 0 |I
REF
| 300nA
50 µV/µA
Input Offset Voltage V
OFFSET
-4.5 +4.5 mV
Input Hysteresis 6mV
Input Bias Current I
BIAS
V
IN
+
= 1.4V, V
IN
-
= 1V -25 +25 nA
Input Offset Current I
OFFSET
2pA
Common-Mode Voltage Range CMVR 0 1.4 V
Common-Mode Rejection Ratio CMRR 80 dB
Comparator Power-Supply
Rejection Ratio
PSRR V
IN
+
= V
IN
-
= 1.4V 80 dB

MAX6457UKD0A+T

Mfr. #:
Manufacturer:
Maxim Integrated
Description:
Supervisory Circuits Single Low C/V Voltage Monitor
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union