CSM_D5F_DS_E_2_2
1
High-precision Optical Switch
D5F
Optical System Achieves 1-μm Operating Position
Repeatability in this 4-way Switch
• No-contact structure for high reliability.
• Ceramic materials in measuring part for superior resistance
to abrasion.
• Two different output types (PNP and NPN) available.
• Less abrasion and damage of mechanical contacts compared
to switches with contacts, reducing fluctuation in the output.
• More compact than previous OMRON models: 40% less mass,
15% lighter across the operating width.
Be sure to read Safety Precautions on page 4 and Safety Precautions for All
Limit Switches.
Ordering Information
Specifications
Ratings Characteristics
Note: The above figures are initial values.
*1. Durability values are calculated at an operating temperature of +5°C to
+35°C, and an operating humidity of 30% to 70%RH. Contact your OMRON
sales representative for more detailed information on other operating
environments.
*2. Measurements were conducted repeatedly at the same point. The value is
1 μm max. for 200 measurements. For other conditions in detail, contact
your OMRON sales representative.
*3. The ambient operating temperature varies depending on the current. Refer
to the following Engineering Data.
* Operating position fluctuation rate for a change of 1°C in the ambient
temperature.
Output configuration Contact form Operation indicator
Cable length
Model
PNP open collector
(+ common)
SPST-NC ON when not operated
1 m D5F-2B10
3 m D5F-2B30
NPN open collector
(− common)
SPST-NO ON when operated
1 m D5F-3C10
3 m D5F-3C30
Power supply
voltage
12 to 24 VDC±10%, ripple (p-p): 10% max.
Output current 100 mA max.
Power
consumption
30 mA max.
Leakage current 0.15 mA max.
Residual voltage 2 V max.
Degree of protection IP67
Durability
*
1
Mechanical
5,000,000 operations min.
Electrical
Operating speed 1 μm/s to 0.5 m/s
Max. operating frequency
60 operations/minute max.
Insulation resistance
100 MΩ min. (at 500 VDC) between each
terminal and non-current-carrying metal part
Dielectric strength
(50/60Hz 1min)
1,100 VAC between each terminal and
non-current-carrying metal part
Vibration
resistance
Malfunction
10 to 500 Hz, 1.3-mm double amplitude
Shock
resistance
Malfunction
300 m/s
2
max.
Repeat accuracy 1 μm max. *2
Ambient temperature *3 Operating: −10°C to +60°C (with no icing)
Ambient humidity Operating: 35% to 95%RH
Weight Switch body: Approx. 50 g; Cord: Approx. 23 g/m
Deviation in electrical durability
after 1,000,000 operations
10 μm max.
Temperature coefficient * ±50 × 10
×6
/°C max.